Permit Information
Permit NumberBLD01-01418
StatusFinaled
Name ST LUKES
Site Address 100 E IDAHO ST
Project NameST LUKES
Customer NumberSTL210523
ePlanReviewNo
Description
(ST LUKES-SOUTH TOWER M.O.B./ASSEMBLY- BASEMENT, SW QUADRANT)(TRANSCRIPTION OFFICE'S REMODEL) To demolish interior non-bearing walls within a 1,958 sq. ft. portion of the existing 40,300 sq. ft. total basement area. To repair perimeter walls of area damaged as a result of demolition with 1-hour fire-resistive construction and finishes per Ch. 8 UBC. To construct full height walls of non-combustible framing with 1-hour fire-resistive construction to create two private offices; infill previous door opening between the remodeled area and GROUP ROOM S1-212 and add new 20 minute assembly exit door into Waiting Room B-02; frame across previous existing 1-hour exit corridor S1-210 to create new office suite; to add a new rated 20 minute smoke / fire doorassembly at entry to S1-227 Reception Room to remove dead end halll; to install a full height N.C., N.B., F.R. wall across one room to create a new Storage Room area and Break Room; to construct a new portion of 1-hour corridor wall from the existing 4 hour area separation wall to the east to meet the existing corridor wall, all to create the TRANSCRIPTION OFFICE SUITE. Within the open suite area, to install non-combustible partions to a height of 6'-2" to create office work stations and access thereto, and brace to floor above; to provide electrical, plumbing, mechanical, fire sprinkler and alarm systems upgrades, all as needed to meet tenant needs and maintain current code compliance for each upgrade or modified system. To install new suspended grid ceiling system, floor finishes and cabinetry. All per notes on and plan review attachments to the approved plans and considered a part of the same. NOTE: This building is fully sprinlered. PC#01-443/drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/6/200112/7/200112/7/2001APASS
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 12/06/2001 at 12:00:43. Contact: ###-####. ok 12/7/2001 12:20:28 PM
BLD-Final12/5/200112/6/200112/6/2001ANR
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 12/05/2001 at 16:31:14. Contact: ###-####...recall 12/6/2001 2:33:31 PM
FIRE-Final Inspection12/4/200112/5/200112/5/2001APASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 12/04/2001 at 16:14:00. Contact: ###-####.
FIRE-Final Inspection11/28/200111/29/200111/29/2001AFAIL
DetailsRick Jackson
Scheduled by a contractor via Hello! on 11/28/2001 at 09:31:56. Contact: ###-####. rated door at corridors; penetrations; damper control; exit signs 11/29/2001 10:37:05 AM
FIRE-Final Inspection11/27/200111/27/200111/27/2001PNR
DetailsTroy Cobbley
No approved fire alarm or fire sprinkler plans on site, no record of completion, main door does not have closer installed. Did not finish inspection 11/27/2001 3:48:23 PM
BLD-Framing/Rough-in10/22/200110/23/200110/23/2001ANR
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 10/22/2001 at 16:17:07. Contact: ###-####...need elec, recall. 10/23/2001 12:01:37 PM
BLD-Framing/Rough-in10/23/200110/23/200110/23/2001PPASS
DetailsCarl Dependahl
Scheduled by Inspector: 340 On 10/23/2001 10:24:58 AM jason ###-#### grid & walls/firestops ok

10/23/2001 5:04:59 PM
BLD-Final10/18/200110/18/200110/18/2001PFAIL
DetailsCarl Dependahl
###-####..not all c/n complete; recall. 10/18/2001 5:15:06 PM
BLD-Framing/Rough-in10/18/200110/18/200110/18/2001AFAIL
DetailsCarl Dependahl
Added by Inspector: 340 On 10/18/2001 3:34:04 PM c/n re ceiling & light supports, recall.
BLD-Framing/Rough-in10/18/200110/18/200110/18/2001AFAIL
DetailsCarl Dependahl
Added by Inspector: 340 On 10/18/2001 3:34:04 PM c/n re ceiling & light supports, recall.
BLD-Framing/Rough-in9/18/20019/18/20019/18/2001APART
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 09/18/2001 at 07:07:20. Contact: ###-####. complete firestops & s/f damper at soth corr wall; chk at clg insp 9/18/2001 3:39:47 PM