Permit Information
Permit NumberBLD01-01593
StatusFinaled
Name BOISE FACTORY OUTLETS (SHELL)
Site Address 6954 S EISENMAN RD
Project NameBOISE FACTORY OUTLET
Customer Number 
ePlanReviewNo
Description
(BOISE FACTORY OUTLETS - SHELL) This building is fire sprinklered for building area increase. To create a 7,631 square foot retail sales tenant space from a larger space. This is a shell permit. The tenant improvement is covered under BLD01-01677. A total of 6,046 square feet is devoted to retail sales. Work is to include a 1-hr tenant demising wall, interior nonbearing walls, 2 restrooms accessible to the disabled, an egress hallway, and suspended ceilings all per approved drawings and plan review conditions on file. Fire sprinkler heads shall be located per NFPA 13-1999 as regulated by the Fire Department. This permit shall not establish a Certificate of Occupancy. PC-0488-01 **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/25/20019/25/20019/25/2001PPASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 09/25/2001 at 07:35:42. Contact: ###-####. final ok card on site. 9/25/2001 3:07:05 PM
BLD-Framing/Rough-in8/30/20018/31/20018/31/2001AFAIL
DetailsJim Storey
###-#### greg this is a re -inspect wires not attched to framing east wall. 9/5/2001 9:16:06 AM
FIRE-Final Inspection8/30/20018/30/20018/30/2001PPASS
DetailsRick Jackson
gregg ###-####
FIRE-Conference8/29/20018/29/20018/29/2001PPART
DetailsRick Jackson
fire for conf-- greg ###-#### requirements for final; sprinklers, alarm and extinguisehrs 8/29/2001 11:02:08 AM
BLD-Framing/Rough-in8/28/20018/28/20018/28/2001PFAIL
DetailsJim Storey
1. (Suspended acoustical tile and lay-in panel ceilings) Metal suspension systems for acoustical tile and for lay-in panel ceilings shall comply with 1997 UBC Standard 25-2 (ASTM C635-69 & C636-69). (1997 UBC 2502.4) Note requirements for seismic bracing.) need wall primitor wires min 12 ga.
BLD-Framing/Rough-in8/1/20018/2/20018/2/2001AFAIL
DetailsJim Storey
r/i- late am????? greg- ###-#### no plan on site city approved. 8/2/2001 11:00:47 AM
BLD-Framing/Rough-in8/2/20018/2/20018/2/2001PPART
DetailsJim Storey
###-#### plans are on site need mech insp for cover ok to proceed upon approval from mech. insp. 8/2/2001 2:31:19 PM