Permit Information
Permit NumberBLD01-03113
StatusVoid/No Violation
Name THE BARBECUE PIT / GREG CRACOLICE
Site Address 6777 W OVERLAND RD
Project Name 
Customer Number 
ePlanReviewNo
Description
*THE BARBECUE PIT T.I.* To maintain and remodel an existing 2,720 sq. ft. facility by removing the interior seating fixture's from the dinning room area, removing the carpet floor covering and painting the concrete floor surface; to reinstall the fixed booths & movable tables and chairs to maintain maximum occupant load of 83 in the dinning area; to modify and add new counters to provide a larger employee work area; to remove the ansul spray system from existing hood and cap the gas lines to the hood area, removing all cooking appliances, and installing steel prep tables; to remove a portion of the east side bearing wall in the existing kitchen area to allow for installation / construction of an enclosed masonry barbeque oven pit with supporting foundations per engineered plans; to upgrade restrooms & interior door hardware to provide increased accessability per appendix chapter 11 UBC; and to add a new 1000 gallon grease interceptor per UPC and West Boise Sewer District. All per approved plans, to include plan review comments, conditions and agreements attached to and part of the approved plans regulating this permit scope and the occupancy of this tenant space. PC#01-894/drs CZN01-00203
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference3/13/20023/13/20023/13/2002APART
DetailsBob Archibald
Conference w/architect and Dan Stewart. P&Z issues addressed with Sahra. Structural an mechanical on plans reviewed. Ron Thurber, architect, will be lead person for owner.
BLD-Conference1/8/20021/8/20021/8/2002APASS
DetailsJim Schmer
ELE01-04260 has been finaled by Jim Schmer.
BLD-Conference1/7/20021/7/20021/7/2002APART
DetailsBob Archibald
Met with Jim Schmer and electrical contractor reviewed electrical requirements and interior non bearing walls that had been opened. No structural issues on interior non bearing walls. Owner was not present.
BLD-Conference12/31/200112/31/200112/31/2001APART
DetailsBob Archibald
Left CN with employee at site that utilities will be terminated if structure is occupied. Jim Schmer reported that buisness was open for lunch on 12/28/01. Outdoor barbeque was in operation and it appeared they were preparing for lunch on this date.
BLD-Other12/31/200112/31/200112/31/2001PPART
DetailsBob Archibald
Returned to site at 3pm. Buisness not in operation and no one present. Photographed sign on front door.
BLD-Conference12/27/200112/27/200112/27/2001 PASS
DetailsJim Schmer
refer to ele01-04260
BLD-Conference12/18/200112/18/200112/18/2001AFAIL
DetailsBob Archibald
Conference with permit holder, informed him that his Temp. Occ. had been revoked and structure was not approved for occupancy. Electrical and Plumbing supervisors were also present and issued CN'S requireing permits and inspections by licensed contractors. A site review of reported inprovements to site confirmed that masonry barbecue was still welded shut, a gas line had been added along the new wall seperating kitchen area from front counter, gas burning appliances in this same area without a hood system, and french frying machine being used under the disconnected type I hood which is in violation of plan review item # s 3 & 4.
BLD-Conference12/18/200112/18/200112/18/2001PPART
DetailsBob Archibald
Returned to site and left copies of Correction Notice at front and rear door listing items for revokation of Temp. Occ.. Notice also mailed to property.
BLD-Conference12/18/200112/18/200112/18/2001APASS
DetailsJim Schmer
Added by Inspector: 324 On 12/27/2001 8:04:31 AM U.A.C.-301.1 Permit required, 305.1 Inspection required / B.C.E.O.- 4-5-08 Permit Applicant (Work done by non-licensed Electrical Contractor, no permit acquired, work covered) Electrical Contractor SHALL obtain permit within 24 hours or further action will be taken (ie: power disconnected to structure) Contractor to call for conference to evaluate work allready doe & covered up.
BLD-Conference12/6/200112/6/200112/6/2001APART
DetailsBob Archibald
Reviewed property for life safety and plan review requirements. Masonry barbecue welded shut, no heat- processing (grease vapor) appliances being used. Informed permit holder to post occ. sign, block access to deck, complete fire dept. requirements and work on conditions required within 90 days. Temp. occ. would be approved on these conditions.
BLD-Final12/5/200112/6/200112/6/2001APART
DetailsTom Arcoraci
fn -- fn gree- ###-####, ###-####, ###-#### ok for temp cn issued 12/6/2001 11:01:15 AM
FIRE-Final Inspection12/5/200112/6/200112/6/2001APASS
DetailsTroy Cobbley
Fire life/safety finaled 12/6/2001 1:57:08 PM