Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD02-00218
StatusFinaled
Name EKC INC
Site Address 113 E CRESTLINE DR
Project Name 
Customer Number 
ePlanReviewNo
Description
this project is an extensive remodel/addition to an existing 1580s.f. 1-story single family dwelling. Work to include the relocation of the garage over head door to the adjacent perpendicular load bearing wall; the addition of 226s.f. to the main level family room and a total of 793s.f. 2nd story addition including a new stair. This project has been fully engineered per the engineering attached. There are to be added footings in the interior crawl area to support new bearing walls per this engineering. There are guardrails proposed using cable intermediate railings.The guardrail work is to be done per the Boise City policy for the Construction of Guardrails with Cable Intermediate Rails Policy dated November 20, 2000. The information to support the rail construction is to be submitted to the structural inspector prior to the framing inspection. Seperate electrical, plumbing, and mechanical permits are required. Smoke detectors per UBC 310.9 are required throughout. All per the approved plans as marked and attached engineering, engineering calculations and conditions list. pep
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/27/20029/30/20029/30/2002PPASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 09/27/2002 at 08:34:41. Contact: ###-####.
BLD-Final9/9/20029/10/20029/10/2002ANR
DetailsTony Young
BLD-Final9/6/20029/9/20029/9/2002ACANC
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 09/06/2002 at 13:22:32. Contact: ###-####. unable to respond by 5 pm 9/9/2002 5:19:26 PM
BLD-Final9/9/20029/9/20029/9/2002AFAIL
DetailsDave Hannah
c/n on site
BLD-Final9/3/20029/3/20029/3/2002PNH
DetailsTony Young
Scheduled by a contractor via Hello! on 09/03/2002 at 10:01:05. Contact: ###-####.
BLD-Energy code compliance5/10/20025/13/20025/13/2002APASS
DetailsRuss Owen
No c/n on site went over items with builder that had been addressed at prior inspection. 5/13/2002 12:49:19 PM
BLD-Energy code compliance5/10/20025/10/20025/10/2002PNR
DetailsTony Young
BLD-Framing/Rough-in5/9/20025/10/20025/10/2002APART
DetailsTony Young
###-#### brian-ok to cover
ok to insulate, c/n on tag 5/10/2002 11:04:58 AM
BLD-Framing/Rough-in5/8/20025/9/20025/9/2002AFAIL
DetailsJim Storey
###-#### ###-####no mech insp. approval no insp. 5/9/2002 12:04:08 PM
BLD-Energy code compliance5/3/20025/6/20025/6/2002APART
DetailsTony Young
###-####
seal ok 5/6/2002 11:17:10 AM
BLD-Framing/Rough-in5/3/20025/6/20025/6/2002APART
DetailsTony Young
###-####
hds ok to cover,, need trades b-4 the rest of framing can be done 5/6/2002 11:18:06 AM
BLD-Framing/Rough-in4/26/20024/29/20024/29/2002APART
DetailsTony Young
todd- ###-#### shear
exterior ok on new part 4/29/2002 12:57:37 PM
BLD-Framing/Rough-in4/29/20024/29/20024/29/2002PPART
DetailsTony Young
shear todd ###-####
new portion ok 4/29/2002 12:58:07 PM
BLD-Other4/25/20024/25/20024/25/2002PPART
DetailsTony Young
Scheduled by a contractor via Hello! on 04/25/2002 at 07:31:50. Contact: ###-####.
OK TO SIDE NEW ADDITION UP TO MSTA STRAPS on NEW TWO STORY, other siding pending msta straps and letter from engineer on existing house walls on hds and existing siding as shear 4/25/2002 2:05:14 PM
BLD-Foundation2/22/20022/22/20022/22/2002PPASS
DetailsTom Arcoraci
###-#### TOOD
BLD-Footing2/20/20022/20/20022/20/2002PPART
DetailsCarl Dependahl
ft insp -todd- ###-####, ext/int ftgs ok to pour...not considered "foothills" 2/21/2002 9:24:20 AM