Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD02-00314
StatusFinaled
Name ICHIBAN STEAK HOUSE RESTAURANT
Site Address 1233 S BROADWAY AVE
Project NameBROADWAY PLAZA
Customer Number 
ePlanReviewNo
Description
(ICHIBAN JAPANESE STEAKHOUSE RESTAURANT) Remodel of an existing 3,998 sq.ft. space for a new (A-3) assembly restaurant tenant per approved plans on file. Work to include structural roof modifications to support new rooftop mechanical equipment, upgrading restrooms to meet current accessibility standards, providing an accessible entrance, some new interior walls, some new interior doors, interior sloped walk at North exit, interior finish, some suspended ceiling work, new walk-in cooler and freezer installations, (7) new Type I hood installations with one-hour rated duct enclosures, a new Type II hood installation, mechanical work including all new rooftop equipment, plumbing work, and electrical work. A CERTIFICATE OFOCCUPANCY IS TO BE ISSUED WHEN COMPLETED AND APPROVED. NOTE: This building is NOT fire sprinklered. (PC#0094-02) JCB
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection8/18/20038/18/20038/18/2003 DONE
DetailsJim Storey
pendind others sign offs. 8/18/2003 8:33:35 AM
DOC - Permit Finaled  8/18/2003 DONE
FIRE-Final Inspection6/18/20026/19/20026/19/2002APASS
DetailsRick Jackson
fire fn dennis- ###-####
BLD-Final6/17/20026/18/20026/18/2002PPART
DetailsJim Storey
Scheduled by a contractor via Hello! on 06/17/2002 at 17:33:41. Contact: ###-####.perm. occ ok pending plm mec and achd. 6/18/2002 3:59:50 PM
FIRE-Final Inspection6/17/20026/18/20026/18/2002ANR
DetailsRick Jackson
Scheduled by a contractor via Hello! on 06/17/2002 at 17:31:43. Contact: ###-####. GC called and said they aren't ready 6/18/2002 1:22:07 PM
BLD-Final6/17/20026/18/20026/17/2002ACANC
DetailsJim Storey
DENNIS ###-#### Disp set to [CANC] by a contractor via Hello! on 06/17/2002 at 17:35:47.
FIRE-Final Inspection6/14/20026/17/20026/17/2002AFAIL
DetailsRick Jackson
cooking area insp- don- ###-####-fn rated door needs to meet 90 min; occupant load sign; extinguishing systems need MAU shutdown; duct detectors installed outside without protection (UL listing? for outside) 6/17/2002 5:10:15 PM
BLD-Framing/Rough-in6/7/20026/10/20026/10/2002APART
DetailsJim Storey
fr dennis ###-#### epoxi bolting special insp from previous c/n still out standing ok to cover cooler exterior walls pending ele and plm approvals. 6/10/2002 10:20:06 AM
BLD-Other6/2/20026/3/20026/3/2002PPART
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 06/02/2002 at 22:14:38. Contact: ###-####....grid ok, combustible framing near hood is "gypped"...awaiting spec insp report(s) for Hilti epoxy anchors.. 6/3/2002 4:23:51 PM
BLD-Framing/Rough-in5/30/20025/30/20025/30/2002PFAIL
DetailsCarl Dependahl
###-####- dennis C/N, VERIFY SHAFTS, PROTECT WOOD W/I 18" OF TYPE 1 HOOD, ADD SEISMIC BRACE AT KITCHEN LID...SPEC INSP FOR HITI ANCHORS & STEEL AT ROOFTOP HVAC. 5/30/2002 4:36:38 PM
BLD-Framing/Rough-in4/22/20024/23/20024/23/2002APART
DetailsJim Storey
dennis ###-#### interior walls only ok for cover. 4/23/2002 11:24:59 AM