Permit Information
Permit NumberBLD02-00427
StatusFinaled
Name ROBERT MAIRS
Site Address 3117 -3119 W CHERRY LN
Project Name 
Customer Number 
ePlanReviewNo
Description
(3117-3119 W CHERRY LN) To convert a single family dwelling to a duplex per approved plans. A moved garage attached to the structure done under a separate permit (BLD02-00423). Work to include new one-hour rated dwelling separation wall, new draft stop above dwelling separation wall, providing attic access for each unit, installing smoke detectors where required, emergency escape/rescue windows in bedrooms where required, and other work as noted on plans. Existing basement for storage use for building owner. (No tenant access.) Inspector discretion for verification and approval of any covered work. Plumbing, Mechanical, and Electrical work to be field verified and approved. To meet Boise City Energy Code. Planning approval per RHJ and Wayne Gibbs. JCB
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/7/20025/8/20025/8/2002APASS
DetailsJim Storey
BLD-Final5/6/20025/7/20025/7/2002AFAIL
DetailsJim Storey
1. FIRE BLOCKING - In combustible construction fire blocking shall be provided (1) In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10-foot intervals both vertical and horizontal, (2) At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings, (3) In concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished, (4) In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials, and (5) at openings between attic spaces and chimney chases for factory-built chimneys. (1997 UBC 708.2.1) Where fire blocks are allowed to be of combustible materials, fireblocking shall consist of 2 inches nominal lumber or two thicknesses of 1-inch nominal lumber with broken lap joints or one thickness of 23/32-inch wood structural panel with joints backed by 23/32-inch wood structural panel. Fire blocks may also be gypsum board, cement fiber board, batts or blankets of mineral or glass fiber, or other approved materials installed in such a manner as to be securely retained in place. (1997 UBC 708.2.2) fur down on living room ceilling provide fire blk. max 10 x 10 spacing.
BLD-Final5/7/20025/7/20025/7/2002PFAIL
DetailsJim Storey
###-#### early pmout of time 5/7/2002 5:10:47 PM
BLD-Framing/Rough-in4/17/20024/18/20024/18/2002APASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 04/17/2002 at 13:23:38. Contact: ###-####. Scheduled by a need to check draft stop at final.contractor via Hello! on 04/17/2002 at 13:23:38. Contact: ###-####. 4/18/2002 11:54:26 AM
BLD-Framing/Rough-in4/11/20024/11/20024/11/2002PNR
DetailsJim Storey
Scheduled by a contractor via Hello! on 04/11/2002 at 10:33:09. Contact: ###-####.