BLD-Final | 1/21/2003 | 1/21/2003 | 1/21/2003 | P | NR |
Tom Arcoraci
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
|
BLD-Final | 1/17/2003 | 1/17/2003 | 1/17/2003 | P | FAIL |
Jim Sly
|
|
|
elliot--for 3221 wildwood; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie nr 1/17/2003 2:56:07 PM
|
BLD-Framing/Rough-in | 9/18/2002 | 9/19/2002 | 9/19/2002 | A | PASS |
Dave Hannah
|
|
|
ELLIOT; Phone #: ###-#### Internet Inspection Request from: Annette Moore insulation ok framing c/n done ok to cover 9/19/2002 11:40:03 AM
|
BLD-Framing/Rough-in | 9/18/2002 | 9/18/2002 | 9/18/2002 | P | PASS |
Jim Sly
|
|
|
Energy OK.
|
BLD-Framing/Rough-in | 9/17/2002 | 9/18/2002 | 9/18/2002 | A | FAIL |
Jim Sly
|
|
|
NR 9/18/2002 11:45:33 AM
|
BLD-Framing/Rough-in | 9/17/2002 | 9/17/2002 | 9/17/2002 | P | FAIL |
Dave Hannah
|
|
|
elliott--; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie c/n itrms not complete 9/17/2002 1:21:12 PM
|
BLD-Framing/Rough-in | 9/11/2002 | 9/12/2002 | 9/12/2002 | A | FAIL |
Dave Hannah
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung c/n on site ok to insulate 9/12/2002 12:08:26 PM
|
BLD-Framing/Rough-in | 8/16/2002 | 8/16/2002 | 8/16/2002 | P | PART |
Dave Hannah
|
|
|
shear wall ok to cover ext wall all but for back walls ok after engin ok 8/19/2002 11:53:23 AM
|
BLD-Framing/Rough-in | 8/15/2002 | 8/15/2002 | 8/15/2002 | P | FAIL |
Dave Hannah
|
|
|
867-*0707 c/n on site needs engineer to evaluate shear panels back wall restaple ares on panels 8/15/2002 5:19:03 PM
|
BLD-Framing/Rough-in | 7/30/2002 | 7/30/2002 | 7/30/2002 | A | PART |
Dave Hannah
|
|
|
1hr fire walls 1st and second floors ok to set
|
BLD-Framing/Rough-in | 7/29/2002 | 7/29/2002 | 7/29/2002 | P | PART |
Russ Owen
|
|
|
clint; Phone #: ###-####2nd floor. 7/29/2002 3:47:26 PM
|
BLD-Framing/Rough-in | 7/19/2002 | 7/22/2002 | 7/22/2002 | A | PART |
Jim Sly
|
|
|
separation wall -clint ###-#### (2) 1hr walls OK. 7/22/2002 11:21:15 PM
|
BLD-Framing/Rough-in | 7/18/2002 | 7/19/2002 | 7/19/2002 | P | CANC |
Dave Hannah
|
|
|
separation wall clint ###-####--per clint cancel re-schedule
|
BLD-Foundation | 7/9/2002 | 7/10/2002 | 7/10/2002 | A | CANC |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 07/09/2002 at 08:12:51. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on 07/10/2002 at 07:15:02.
|
BLD-Foundation | 7/10/2002 | 7/10/2002 | 7/10/2002 | P | PART |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 07/10/2002 at 07:16:06. Contact: ###-####.rebar in forms about 80% complete 7/10/2002 2:52:04 PM
|
BLD-Footing | 7/9/2002 | 7/9/2002 | 7/9/2002 | P | PART |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 07/09/2002 at 08:12:13. Contact: ###-####. work in progress setbacks ok 7/9/2002 12:59:59 PM
|