BLD-Final | 5/29/2009 | 5/29/2009 | 5/29/2009 | P | PASS |
Bob Archibald
|
|
|
Fire alarm and sprinker requirements completed. FIR02-00515 & 00451
|
BLD-Aging Inspection | 3/1/2004 | 3/1/2004 | 3/1/2004 | | DONE |
Dave Hannah
|
|
|
|
BLD-Conference | 7/22/2003 | 7/22/2003 | 7/22/2003 | P | PASS |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 7/22/2003 at 11:10:16 AM. Contact: ###-####.w/ arch at site: need dampers at bsmt occupancy separation as per c/n. 7/22/2003 3:18:19 PM
|
BLD-Conference | 6/2/2003 | 6/4/2003 | 6/4/2003 | P | CANC |
Carl Dependahl
|
|
|
|
BLD-Final | 5/30/2003 | 6/2/2003 | 6/2/2003 | A | PART |
Carl Dependahl
|
|
|
###-####
|
BLD-Final | 3/20/2003 | 3/20/2003 | 3/20/2003 | A | PART |
George Slane
|
|
|
ok for temp. occ.
|
FIRE-Final Inspection | 3/20/2003 | 3/20/2003 | 3/20/2003 | P | PART |
Rick Jackson
|
|
|
temp occ aprroved per agreementletter to interconnect standpipes and monitor tampers in basement
|
BLD-Final | 3/14/2003 | 3/17/2003 | 3/17/2003 | A | FAIL |
Carl Dependahl
|
|
|
###-####; keep c/n....arch to clarify occupancy separation...(s/f dampers, elevator lobby at bsmt?) 3/17/2003 1:19:36 PM
|
FIRE-Final Inspection | 3/14/2003 | 3/17/2003 | 3/17/2003 | A | FAIL |
Rick Jackson
|
|
|
###-#### ###-#### need alternate floor elevator recall; monitor all tampers; sprinkler all areas; interconnect all standpipes; install alarm notification in all walkways and lobbies; need alarm notification on second floor open office area; 3/17/2003 10:45:49 AM
|
BLD-Final | 3/13/2003 | 3/14/2003 | 3/14/2003 | A | NR |
Carl Dependahl
|
|
|
###-####...keep c/n (fire final...?)
3/14/2003 5:04:02 PM
|
BLD-Final | 3/13/2003 | 3/14/2003 | 3/14/2003 | A | NR |
Carl Dependahl
|
|
|
###-####...keep c/n re fire; struct. issues ok 3/17/2003 1:14:09 PM
|
FIRE-Final Inspection | 3/13/2003 | 3/14/2003 | 3/14/2003 | A | CANC |
Rick Jackson
|
|
|
###-####
|
BLD-Final | 3/6/2003 | 3/7/2003 | 3/7/2003 | A | FAIL |
Carl Dependahl
|
|
|
###-####...c/n obtain fire, complete misc items, post occ load at training rm; egress/access controll devices (OFOI) to be approved (N.I.C?) 3/7/2003 3:42:02 PM
|
BLD-Final | 3/5/2003 | 3/6/2003 | 3/6/2003 | A | NR |
Carl Dependahl
|
|
|
###-####...no insp, need fire ok, etc. 3/6/2003 3:48:19 PM
|
FIRE-Final Inspection | 3/5/2003 | 3/6/2003 | 3/6/2003 | A | FAIL |
Rick Jackson
|
|
|
###-#### need timeline for fixing standpipe interconnection and sprinklering all areas; remove head in east comm room; need standard response sprinklers on second floor as QR's were installed; need max occupant load sign in training room 3/6/2003 1:02:30 PM
|
BLD-Conference | 2/11/2003 | 2/11/2003 | 2/11/2003 | P | PASS |
Carl Dependahl
|
|
|
scott...re T/O....need all trade ok's 2/11/2003 2:40:43 PM
|
BLD-Conference | 1/30/2003 | 1/31/2003 | 1/31/2003 | P | PASS |
Carl Dependahl
|
|
|
grid reinsp...ok, braces added 1/31/2003 3:32:32 PM
|
BLD-Framing/Rough-in | 1/29/2003 | 1/30/2003 | 1/30/2003 | A | NR |
Carl Dependahl
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung...need elec ok'd; add braces at t.o.w. ...some missed; chk spreaders at final 1/30/2003 1:51:18 PM
|
BLD-Framing/Rough-in | 1/30/2003 | 1/30/2003 | 1/30/2003 | P | PART |
Carl Dependahl
|
|
|
###-####
|
BLD-Framing/Rough-in | 1/30/2003 | 1/30/2003 | 1/30/2003 | P | CANC |
Carl Dependahl
|
|
|
grid reinsp.
|
BLD-Framing/Rough-in | 12/19/2002 | 12/20/2002 | 12/20/2002 | A | PART |
Carl Dependahl
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung; int partitions,floor penetrations, ok ; verbal for arch to investigate hvac penetrations at east stair enclosure. 12/20/2002 1:06:02 PM
|
BLD-Framing/Rough-in | 12/10/2002 | 12/11/2002 | 12/11/2002 | A | NR |
Carl Dependahl
|
|
|
###-####
|
BLD-Framing/Rough-in | 12/11/2002 | 12/11/2002 | 12/11/2002 | P | PART |
Carl Dependahl
|
|
|
8694101 scott...SEAL PLBG FL. PENETRATIONS...OK TO 1 SIDE. NEED FIRE SPRINKLER INSP. PRIOR TO CEILING COVER; HAS HVAC PENETRATION AT EAST STAIR ENCLOSURE... 12/11/2002 3:56:18 PM
|
BLD-Conference | 11/5/2002 | 11/6/2002 | 11/6/2002 | A | DONE |
Tom Arcoraci
|
|
|
Scott cn issued by 340 11/6/2002 8:46:29 AM 11/6/2002 8:47:15 AM
|