Permit Information
Permit NumberBLD02-02178
StatusFinaled
Name SOMERSET HILLS APARTMENTS (BLDG 12)
Site Address 390 W CRESTLINE DR
Project NameSOMERSET HILLS-BLDG 12
Customer Number 
ePlanReviewNo
Description
SOMERSET HILLS APARTMENTS-BLDG 12 * To add a new gas fired furnace in each apartment unit, shorteen full height nonbearing wall at kitchen and add eating bar, add a 8' X 12' exterior deck to the two bedroom and three bedroom units, add entry cover to each entry stair. Additional work covered with this permit include framing interior walls and dropped ceiling to enclose furnaces and cover duct work. All construction per the approved plans, attached engineering calculations and inspectors approvals. NOTE: The installation of smoke detectors are required to be installed in all sleeping rooms and rooms providing access to to sleeping rooms per UBC Section 310.9.1.2, UFC Section 1007.2.9.2. MJP
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection11/15/200611/15/200611/17/2006 PASS
DetailsTony Young
BLD-Aging Inspection9/14/20069/14/20069/19/2006 PASS
DetailsTony Young
BLD-Aging Inspection7/10/20067/10/20067/11/2006 PASS
DetailsTony Young
BLD-Aging Inspection5/8/20065/8/20065/10/2006 PASS
DetailsTony Young
FIRE-Final Inspection3/6/20063/6/20063/6/2006PPASS
DetailsForrest France
The required corrections have been completed, life safety finaled.
FIRE-Final Inspection2/28/20062/28/20063/1/2006PDEFR
DetailsForrest France
Inspection to be completed 3/1.
FIRE-Final Inspection3/1/20063/1/20063/1/2006APART
DetailsForrest France
Door closures have been adjusted, SD have been relocated in some units as required, exhaust fans have been connected to the light switch in the bathrooms, the smoke detectors in unit 422 have NOT been relocated to proper locations as required, no access to three units at this time due to tenant occupation.
FIRE-Final Inspection2/1/20062/1/20062/1/2006PFAIL
DetailsForrest France
Door closures at some locations need adjustment, smoke detectors must meet the requirements of NFPA 72 2002 11.8.3.1 and 11.8.3.5 with respect to location, fire dept. access and building addressing are acceptable.
BLD-Aging Inspection1/24/20061/24/20061/25/2006 PASS
DetailsTony Young
BLD-Conference11/24/200511/24/200511/25/2005ACANC
DetailsTony Young
Phone #: ###-####
BLD-Aging Inspection11/24/200511/24/200511/24/2005 CANC
DetailsTony Young
BLD-Aging Inspection9/12/20059/12/20059/12/2005 PART
DetailsDave Hannah
wip
BLD - Request for Extension7/5/20057/6/20057/6/2005 PASS
DetailsTony Young
rob danielson ###-#### or ###-#### still working on this project please call him
BLD-Aging Inspection5/12/20055/12/20055/12/2005 PASS
DetailsTony Young
BLD - Request for Extension2/25/20052/28/20052/28/2005ADONE
DetailsTroy James
mark; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Aging Inspection11/3/200411/3/200411/3/2004 CANC
DetailsTroy James
BLD-Aging Inspection9/1/20049/1/20049/1/2004 PART
DetailsTroy James
BLD-Aging Inspection6/22/20046/22/20046/22/2004 DONE
DetailsTroy James
wip 6/22/2004 11:54:32 AM
BLD-Framing/Rough-in3/25/20043/25/20043/25/2004PCANC
DetailsDave Hannah
warren; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Framing/Rough-in1/14/20041/15/20041/15/2004APART
DetailsTony Young
WARREN ; Phone #: ###-#### Internet Inspection Request from: Annette Moore
#s 420, 421, 422, 423 ok to cover 1/15/2004 11:40:06 AM
BLD-Aging Inspection10/1/200310/1/200310/1/2003 PASS
DetailsTony Young
wip 10/1/2003 10:05:50 AM
BLD-Framing/Rough-in3/31/20034/1/20034/1/2003PPART
DetailsJim Storey
Scheduled by a contractor via Hello! on 3/31/2003 at 1:55:32 PM. Contact: ###-####.ok to insulate need fire blk/and mrch r/i. 4/1/2003 3:23:10 PM