Permit NumberBLD02-02813
StatusFinaled
Name TABLEROCK PRINTING CO
Site Address 1115 W GROVE ST
Project NameWELSH CENTER
Customer Number 
ePlanReviewNo
Description
(TABLEROCK PRINTING COMPANY) To finish a 10,409 sq.ft. for a printing business per approved plans. Room usage includes sales, office, work area and storage. Restrooms for this tenant are available on the 2nd floor accessed by elevator. Work will include construction of interior partitions, installation of suspended ceiling system, miscelaneous related interior finishes. NOTE: This building is fully fire sprinklered for area increase, any alterations or modifications to the sprinkler system shall be per NFPA #13 as regulated by the fire department. NO STORAGE RACKS OVER EIGHT FEET HIGH WILL BE ALLOWED WITHOUT A SEPARATE PERMIT. (pc#733-02) rmh
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/24/20036/24/20036/24/2003PPASS
DetailsCarl Dependahl
rory; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Final6/17/20036/18/20036/18/2003AFAIL
DetailsCarl Dependahl
rory; Phone #: ###-#### Internet Inspection Request from: Barbara Moore, need firestops installed per c/n 6/18/2003 12:13:53 PM
BLD-Final6/16/20036/16/20036/16/2003PFAIL
DetailsCarl Dependahl
###-#### rory...firestop 2hr wall penetrations, protect hvac ducts at ramp side of 2hr wall 6/16/2003 4:25:42 PM
BLD-Final6/13/20036/13/20036/16/2003PCANC
DetailsCarl Dependahl
###-####
BLD-Final6/12/20036/13/20036/13/2003ACANC
DetailsTom Arcoraci
###-#### rory 6/13/2003 8:01:16 AM needs fire 6/13/2003 8:01:26 AM
FIRE-Final Inspection6/13/20036/13/20036/13/2003PPASS
DetailsRick Jackson
FIRE-Final Inspection3/12/20033/13/20033/13/2003AFAIL
DetailsRick Jackson
RORY; Phone #: ###-#### Internet Inspection Request from: Darla Downs need alarm plans as duct detectors were installed without plans by Peak 3/13/2003 10:15:18 AM
FIRE-Final Inspection2/5/20032/5/20032/5/2003PFAIL
DetailsRick Jackson
RICK; Phone #: ###-#### Internet Inspection Request from: Darla Downs need exit sign above new corridor for second exit; need hazmat/flammable liquid list; hardwire all equipment currently using extension cords; need alarm plans submitted for duct detectors; "Door to remain...." sign at main exit 2/5/2003 4:08:36 PM
FIRE-Conference1/31/20031/31/20031/31/2003ADONE
DetailsTroy Cobbley
I spoke with the contractor, Rick, and told him that the sprinkler riser needs to have its annual inspection as well as the fire sprinkler monitoring system. Also there are new duct smoke detectors on the new hvac system and that they would need to be connected to the existing fire alarm panel and that this work would require approved drawings and permits
BLD-Framing/Rough-in1/8/20031/8/20031/8/2003PPART
DetailsCarl Dependahl
###-#### rory, c/n issued, clarify or install corridor & occ. separation wall to deck, get sprinkler r/i. OK to cover unaffected int partitions. 1/8/2003 5:33:43 PM