Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD03-01231
StatusFinaled
Name HYDE PARK PLACE
Site Address 1207 W FORT
Project NameHyde Park Place
Customer Number 
ePlanReviewNo
Description
Hyde Park Place * To construct a new 39 unit, three story, wood frame, multi-family, apartment building, above a three-hour horzontal assembly meeting the requirements of Section 508.2-1. All construction per the approved plans and attached comment list. NOTE: This building is required to be fire sprinklered per NFPA 13-R. Three units are below 800 sq.ft. in area. ACHD FEES ARE REQQUIRED TO BE COLLECTED ON THIS PERMIT. PC#307-03 DRH 02-00221 CUP02-00096
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy 5/26/20045/26/2004 DONE
Details
BLD-Final5/19/20045/20/20045/20/2004APASS
DetailsDave Hannah
FRANKO; Phone #: ###-#### Internet Inspection Request from: Annette Moore ok for perm occ 5/21/2004 10:31:21 AM
BLD-Final5/6/20045/7/20045/7/2004AFAIL
DetailsDave Hannah
Cathy has the card - David Southers, ###-#### if questions still needs to finish in stalling hand rails 5/7/2004 11:20:34 AM
BLD-Final4/8/20044/8/20044/8/2004PPART
DetailsDave Hannah
darrell; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok for temp occ ok for perm occ after others go final and hand rails installed 4/8/2004 5:22:06 PM
BLD-Final4/2/20044/5/20044/5/2004AFAIL
DetailsDave Hannah
darryl; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
FIRE-Final Inspection4/2/20044/5/20044/5/2004APASS
DetailsRick Jackson
darryl; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Framing/Rough-in3/16/20043/16/20043/16/2004APART
DetailsDave Hannah
ceilling grid in garage ok to start dropping in panels 3/16/2004 10:35:43 AM
BLD-Framing/Rough-in12/4/200312/5/200312/5/2003APART
DetailsDave Hannah
BLD-Framing/Rough-in12/4/200312/4/200312/4/2003PPART
DetailsDave Hannah
Darrell; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
FIRE-Conference11/20/200311/21/200311/21/2003APART
DetailsRick Jackson
Jim; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes about exit/emergency lights in basement and corridors and identified with electrical contractor 11/21/2003 2:27:46 PM
BLD-Framing/Rough-in11/17/200311/17/200311/17/2003PPART
DetailsDave Hannah
Darrell; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes int walls that need shear ok to insulate 11/17/2003 4:44:59 PM
BLD-Conference10/14/200310/14/200310/14/2003PDONE
DetailsDave Hannah
darryl; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Conference10/14/200310/14/200310/14/2003PPART
DetailsAlan Hauser
meet with hvac contractor about new heating systems 10/14/2003 2:03:40 PM went over heating system and duct to be allowed, bldg super to find out icbo decision on use of air connector ducting 10/14/2003 6:15:20 PM
BLD-Conference9/17/20039/17/20039/17/2003PDONE
DetailsDave Hannah