BLD-Final | 9/27/2004 | 9/27/2004 | 9/27/2004 | P | PART |
Lane Manuel
|
|
|
tim; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
temp c of o OK.
Permanent Cof O is OK pending zoning/code enf. approval 9/27/2004 1:21:18 PM
|
Code Occupancy Approval | 9/29/2004 | 9/27/2004 | 9/27/2004 | A | PASS |
Scott M.Brown
|
|
|
FINAL SIGNED OFF 9/29/2004 10:03:03 AM
|
Permanent Occupancy | | 9/27/2004 | 9/27/2004 | | DONE |
|
|
|
|
BLD-Final | 9/24/2004 | 9/24/2004 | 9/24/2004 | P | NR |
Lane Manuel
|
|
|
tim; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
mechanical issues to be addressed prior to bldg final 9/24/2004 4:30:17 PM
|
FIRE-Final Inspection | 9/24/2004 | 9/24/2004 | 9/24/2004 | P | PASS |
Troy Cobbley
|
|
|
Fire life safety finaled
|
BLD-Final | 9/17/2004 | 9/17/2004 | 9/17/2004 | P | FAIL |
Lane Manuel
|
|
|
Tim; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
left c/n 9/17/2004 3:45:00 PM
|
Code Occupancy Approval Temp | 9/17/2004 | 9/17/2004 | 9/17/2004 | P | DONE |
Scott M.Brown
|
|
|
NO CHILD CARE AUTHORIZED WITH THIS TEMP OCCUPANCY AS FENCED PLAY AREA REQUIRED.
|
BLD-Framing/Rough-in | 9/1/2004 | 9/1/2004 | 9/1/2004 | P | PASS |
Lane Manuel
|
|
|
ceiling grid --tim ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
need copy of architects astm change to '97 susp. ceiling standards. gave ok to cover 9/1/2004 3:43:45 PM
|
BLD-Framing/Rough-in | 8/25/2004 | 8/26/2004 | 8/26/2004 | A | PART |
Jim Storey
|
|
|
tim; Phone #: ###-#### Internet Inspection Request from: Annette Moore ok for border tile only/firedampers void fire chalking installed/missing insulation at soffits north and south/no light wires instaled throught grid/ arch to submit astm for pods and rivets. 8/26/2004 9:30:41 AM
|
BLD-Other | 8/9/2004 | 8/9/2004 | 8/9/2004 | P | DONE |
Troy Cobbley
|
|
|
I issued a citation to Romar Electric/Kurtis Carlson for violation of IFC 902.1 as adopted by Boise City Municipal Code section 7-01-02 for beginning installation of the fire alarm system without approved plans.
|
FIRE-Conference | 8/6/2004 | 8/6/2004 | 8/6/2004 | P | DONE |
Troy Cobbley
|
|
|
I issued a stop work order for the fire alarm installation. Notice is posted on the southeast facing door
|
BLD-Framing/Rough-in | 7/16/2004 | 7/16/2004 | 7/16/2004 | P | PASS |
Jim Sly
|
|
|
tim; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Inspection from new approved re-submittal plans ....appears to be OK. 7/16/2004 2:59:58 PM
|
BLD-Framing/Rough-in | 7/13/2004 | 7/14/2004 | 7/14/2004 | A | PART |
Jim Sly
|
|
|
###-#### TIM Looked at areas for frame as approved on original approved plans ....OKd that area for cover. Still waiting for New plan resubmittal so we can inspect other areas. 14/2004 9:18:47 AM 7/14/2004 9:23:52 AM
|
BLD-Framing/Rough-in | 7/1/2004 | 7/1/2004 | 7/1/2004 | P | FAIL |
Jim Sly
|
|
|
###-#### Tim C/N Framing insp for Misc framing corrections......Went so far to find out that Not per approved plans..... Resubmit for plan modification to PDS dept. Do Not Build Beyond original Approved Plan. 7/1/2004 1:57:29 PM
|
BLD-Framing/Rough-in | 6/29/2004 | 6/29/2004 | 6/29/2004 | P | NR |
Tom Arcoraci
|
|
|
Ken; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
|
BLD-Framing/Rough-in | 6/23/2004 | 6/23/2004 | 6/23/2004 | P | PART |
Jim Sly
|
|
|
tim; Phone #: ###-#### Internet Inspection Request from: Annette Moore Roof nailing OK. 6/23/2004 1:50:56 PM
|
BLD-Footing | 6/11/2004 | 6/11/2004 | 6/11/2004 | P | PART |
Dixie Fellows
|
|
|
ken; Phone #: ###-#### Internet Inspection Request from: Barbara Moore inspected by MIT 6/11/2004 3:18:05 PM
|
BLD-Foundation | 5/25/2004 | 5/26/2004 | 5/26/2004 | A | PART |
Jim Sly
|
|
|
kem; Phone #: ###-#### Internet Inspection Request from: Annette Moore Pending special insp and approvals....MTI 5/26/2004 11:03:38 AM
|
BLD-Footing | 5/24/2004 | 5/24/2004 | 5/24/2004 | P | PART |
Jim Sly
|
|
|
Tim; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes Contractor wanted me to approve removal of a large section of N/S wall bordering corridor and bookstore....... Needs plan modification. If contractor continues to pour footings, Boise City will require (at a Min.) New "Stamped" Engineering for affected areas, and Special inspection of footings, wall and reinforcment. C5/24/2004 2:28:18 PM 5/24/2004 2:37:07 PM
|
BLD-Aging Inspection | 4/20/2004 | 4/20/2004 | 4/20/2004 | | CANC |
Russ Owen
|
|
|
|