BLD-Final | 3/29/2004 | 3/29/2004 | 3/29/2004 | P | PASS |
Jim Storey
|
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Darla Downs final ok card on site. 3/29/2004 3:15:52 PM
|
FIRE-Final Inspection | 3/29/2004 | 3/29/2004 | 3/29/2004 | P | PASS |
Rick Jackson
|
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
BLD-Final | 3/23/2004 | 3/23/2004 | 3/23/2004 | P | FAIL |
Jim Storey
|
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Barbara Moore exit hardware/ada sink/valve handles/cabnet height/bathrm base. 3/23/2004 4:30:20 PM
|
FIRE-Final Inspection | 3/23/2004 | 3/23/2004 | 3/23/2004 | P | FAIL |
Rick Jackson
|
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Exit door hardware reviewed with architect, GC and Jim Storey 3/23/2004 4:28:44 PM
|
Code Occupancy Approval | 3/15/2004 | 3/15/2004 | 3/15/2004 | P | PASS |
Wm. Michael Meloy
|
|
|
Compliance met. 3/15/2004 3:39:22 PM
|
BLD-Framing/Rough-in | 2/17/2004 | 2/17/2004 | 2/17/2004 | P | FAIL |
Jim Storey
|
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Annette Moore 18. Accessible Shower – Transfer- type shower compartments shall be 36 inches wide by 36 inches
deep inside finished dimension, measured at the center point of opposing sides, and shall have a
minimum 36 inches wide entry on the face of the shower compartment. The clearance in front of
the compartment shall be 48 inches long minimum measured from the control wall and 36
inches wide minimum. (Cabo/Ansi A117.1 Sec. 608.2) Please provide the 48 inches
maneuvering clearance required in front of the accessible shower unit. Note that this
dimension is measured from the wall of the shower that has the controls located on it. plm void and needs reinsp after c/n/ need plan dimetioned to show compliance with plan review note 18# 2/17/2004 3:21:37 PM ok to cover all but restaroom area. 2/17/2004 3:29:14 PM
|
Permanent Occupancy | | 3/29/2003 | 3/29/2003 | | DONE |
|
|
|
|