BLD-Final | 11/29/2004 | 11/29/2004 | 11/29/2004 | P | PASS |
Lane Manuel
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice
|
BLD-Final | 11/24/2004 | 11/26/2004 | 11/26/2004 | A | FAIL |
Jim Storey
|
|
|
rob sr; Phone #: ###-#### Internet Inspection Request from: Barbara Moore no access/b-vent to close to door astracal. 11/26/2004 9:46:14 AM
|
BLD-Final | 11/26/2004 | 11/26/2004 | 11/26/2004 | P | FAIL |
Jim Storey
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice 6 inch clearance astrecal to b-vent. 11/26/2004 3:01:20 PM
|
BLD-Energy code compliance | 11/1/2004 | 11/2/2004 | 11/2/2004 | A | FAIL |
Troy James
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice
Need to insulate at bay window second level, and install insulation behind corner and perpindicular wall cavities. 11/2/2004 9:12:45 AM
|
BLD-Energy code compliance | 11/2/2004 | 11/2/2004 | 11/2/2004 | A | PASS |
Troy James
|
|
|
|
BLD-Framing/Rough-in | 11/1/2004 | 11/1/2004 | 11/1/2004 | P | FAIL |
Troy James
|
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice
actually energy inspection, not ready 11/1/2004 2:00:54 PM
|
BLD-Framing/Rough-in | 10/29/2004 | 10/29/2004 | 10/29/2004 | P | PASS |
Tom Arcoraci
|
|
|
justin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD-Wall cover | 10/25/2004 | 10/26/2004 | 10/26/2004 | A | PASS |
Jim Storey
|
|
|
garage; Phone #: ###-#### Internet Inspection Request from: Linda Hartwell
|
BLD-Foundation | 9/8/2004 | 9/9/2004 | 9/9/2004 | A | PASS |
Tom Arcoraci
|
|
|
jerry; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie wip ok 9/9/2004 9:12:05 AM
|
BLD-Footing | 9/8/2004 | 9/8/2004 | 9/8/2004 | P | PASS |
Jim Storey
|
|
|
jerry; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD-Footing | 9/2/2004 | 9/2/2004 | 9/2/2004 | P | NR |
Jim Storey
|
|
|
dane; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|