Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberBLD04-01485
StatusFinaled
Name VERTICAL CONSTRUCTION
Site Address 1825 N CLAREMONT DR
Project Name 
Customer Number 
ePlanReviewNo
Description
"1/31/2005 THIS PERMIT IS MODIFIED TO REFLECT THE DEMO AND RECONSTRUCTION OF A BEDROOM AREA. THIS NEW WORK ADDS VALUE TO THE ORIGINAL PERMIT OF $40,000 1/31/2005 pep" This project is for the razing of 672s.f. of existing single family dwelling and addition of 2273s.f. on 2-levels and 927s.f. garage and mechanical room. "THE PERMIT HOLDER IS RESPONSIBLE TO COMPLY WITH CURRENT WALL BRACING REQUIREMENTS AS ADOPTED BY BOISE CITY" R-1B ok per cfh04-00014 by map. Separate electrical, plumbing, mechanical and ESC permits are required. per Terry Records foundation subgrade is to be approved by engineer prior to placeing of concrete. All per the approved plans as marked, REScheck foundation engineering dated 6/29/2004, along with ESC pland and requirements. pep
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/29/20056/29/20056/30/2005PPASS
DetailsDave Hannah
todd; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
DOC - Permit Finaled6/30/20056/30/20056/30/2005PPASS
DetailsDave Hannah
BLD-Grading Inspection6/29/20056/29/20056/29/2005 BOND
The grading has been completed in substantial compliance with the approved plan. However, revegetation of the slopes has not been completed. For this the engineer has recommended a
$500.00 bond. The grading can be conditionally approved upon receipt of the $500.00 bond.
BLD-Energy code compliance2/16/20052/17/20052/17/2005APASS
DetailsTroy James
Scheduled by a contractor via Hello! on 2/16/2005 at 12:03:40 PM. Contact: ###-####.
BLD-Energy code compliance2/14/20052/14/20052/14/2005PFAIL
DetailsTroy James
Scheduled by a contractor via Hello! on 2/14/2005 at 9:26:57 AM. Contact: ###-####. incorrect R-value as required per energy calcs, need report from foam insulation spray at ceiling line 2/14/2005 2:40:52 PM
BLD-Framing/Rough-in2/14/20052/14/20052/14/2005PPASS
DetailsTroy James
Scheduled by a contractor via Hello! on 2/14/2005 at 9:27:24 AM. Contact: ###-####.
BLD-Wall cover2/14/20052/14/20052/14/2005PCANC
DetailsTroy James
Scheduled by a contractor via Hello! on 2/14/2005 at 9:26:24 AM. Contact: ###-####.
BLD-Framing/Rough-in2/8/20052/9/20052/9/2005PPASS
DetailsTroy James
Todd; Phone #: ###-#### Internet Inspection Request from: Jan Rice
BLD-Framing/Rough-in2/4/20052/7/20052/7/2005PFAIL
DetailsLane Manuel
Todd; Phone #: ###-#### Internet Inspection Request from: Jan Rice
c/n posted on window next to front door.
2/7/2005 4:18:56 PM
BLD-Conference12/29/200412/29/200412/29/2004PPART
DetailsTroy James
setbacks for marlene, verified setbacks are at 10' from house with 4' overhang projecting into property line, adjacent neighbor landscaping projecting 3' over property line. 12/29/2004 3:52:13 PM
BLD-Foundation10/11/200410/12/200410/12/2004APASS
DetailsTroy James
Scheduled by a contractor via Hello! on 10/11/2004 at 12:29:36 PM. Contact: ###-####.
BLD-Footing10/8/200410/8/200410/8/2004PPASS
DetailsTroy James
jed--after 3:30??? ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD-Foundation9/24/20049/27/20049/27/2004APART
DetailsTroy James
Scheduled by a contractor via Hello! on 9/24/2004 at 3:07:41 PM. Contact: ###-####. North wall and garage door front ok to place concrete. 9/27/2004 10:28:36 AM
BLD-Footing9/21/20049/22/20049/22/2004APASS
DetailsTroy James
Scheduled by a contractor via Hello! on 9/21/2004 at 11:37:28 AM. Contact: ###-####.
BLD-Footing9/17/20049/20/20049/20/2004ANR
DetailsDave Hannah
Mark; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
BLD-Footing9/17/20049/17/20049/17/2004PCANC
DetailsTroy James
BLD-Grading Inspection9/17/20049/17/20049/17/2004 DONE
Footing subgrade for the garage and west pool wall have been approved by the geotechnical engineer