Permit Information
Permit NumberBLD04-01819
StatusFinaled
Name DBSI OFFICE
Site Address 7000 W STATE ST
Project NameNORTHGATE SHOP CENTER
Customer Number 
ePlanReviewNo
Description
(DBSI OFFICE)(NORTHGATE SHOPPING CENTER) To remodel a 34,069 sq.ft. tenant space previously occupied by a retailer for office per approved plans. Work to include relocation of exterior exit door, new interior bearing wall, construction of new accessible restrooms, Miscelaneous related interior finishes. (pc#511-04) rmh
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy 5/22/20055/22/2005 DONE
Details
FIRE-Final Inspection3/22/20053/22/20053/22/2005PPASS
DetailsTroy Cobbley
Fire life safety finaled. Fire alarm and fire sprinkler finaled
BLD-Final10/4/200410/5/200410/5/2004APASS
DetailsTom Arcoraci
dennis; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok for perm when others sign perm occ 10/5/2004 8:34:08 AM
BLD-Final10/1/200410/4/200410/4/2004AFAIL
DetailsDave Hannah
dennis--pending fire ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie needs to finish handrails and get fire l/s c/n items completed 10/4/2004 10:58:25 AM
FIRE-Final Inspection10/4/200410/4/200410/4/2004PPART
DetailsTroy Cobbley
Life safety items complete. A temporary occupancy was given with dave millers and teresa's permission until the fire alarm and fire sprinklering of the outside canopies have been finished 10/4/2004 3:24:35 PM
FIRE-Final Inspection10/1/200410/4/200410/4/2004AFAIL
DetailsTroy Cobbley
Provide approved door hardware on one of the two front entrances. See review comments #8. Rmove manual flush bolts from both main exits. Provide approved door hardware on door to storage and old dressing room doors. Provide emergency lighting on second floor, stairway and breakroom that is the egress path. Repair four exit signs. Provide emergency lights in the northeast corner and the short exit corridor. Provide exit sign in the other short exit corridor. 9/4/2004 9:40:30 AM
BLD-Other9/29/20049/29/20049/29/2004PPART
DetailsTony Young
dennis t-grid inspection; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ok pending trades 9/29/2004 4:22:02 PM
FIRE-Sprinkler Rough-in9/29/20049/29/20049/29/2004PFAIL
DetailsTroy Cobbley
I spoke to Dave Miller and he has not heard back from Teresa about approval of the bond so no inspection was performed. Per Dave all life safety items will need to be complete prior to any temporyary occupancy being given. This was passed on to Dennis with HC. 9/29/2004 3:03:06 PM
BLD-Framing/Rough-in9/23/20049/24/20049/24/2004APASS
DetailsTroy James
Scheduled by a contractor via Hello! on 9/23/2004 at 5:39:13 PM. Contact: ###-####.
FIRE-Sprinkler Rough-in9/23/20049/24/20049/24/2004ACANC
DetailsTroy Cobbley
I spoke to dennis about there is to be no fire signoffs until the sprinklers in the canopies and the fire alarm system has been installed and approved. 9/24/2004 12:20:19 PM
BLD-Framing/Rough-in9/22/20049/23/20049/23/2004PFAIL
DetailsTroy James
dennis; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
Need to install (3) 17/8x117/8 LVL at hallway to restrooms or provide letter from engineer stating what is installed is ok. Ok to cover except at beam location. 9/23/2004 4:37:53 PM
BLD-Conference9/21/20049/21/20049/21/2004PDONE
DetailsTroy Cobbley
I left a notice with Dutch with DBSI that states that there will not be any more inspection sign offs or plan review on this tenant space or any others in the shopping center until the fire alarm system and sprinkler systems have met code requirements as enforced by boise fire dept.
BLD-Foundation9/17/20049/20/20049/20/2004APART
DetailsTony Young
dennis; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
int. ftg for moved bearing on existing 9/20/2004 10:07:19 AM
FIRE-Conference9/17/20049/20/20049/20/2004ADONE
DetailsTroy Cobbley
I spoke to Dutch with DSCI about sprinkler heads. I found several locations where sprinklers are overspaced. I told him he needs a sprinkler contractor to verify spacing throughout the tenant space. Also there is a control valve on a anti-freeze loop that does not have a tamper switch. 9/20/2004 2:47:09 PM