BLD-Final | 5/24/2005 | 5/24/2005 | 5/24/2005 | A | PASS |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 5/24/2005 at 7:28:09 AM. Contact: ###-####. ok for perm occ
|
Permanent Occupancy | | 5/24/2005 | 5/24/2005 | | DONE |
|
|
|
|
BLD-Conference | 5/6/2005 | 5/6/2005 | 5/6/2005 | P | DONE |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 5/6/2005 at 8:02:30 AM. Contact: ###-####.
|
BLD-Conference | 4/11/2005 | 4/11/2005 | 4/11/2005 | P | DONE |
Dave Hannah
|
|
|
dave ###-#### cable gaurd rails 4/11/2005 2:23:54 PM
|
BLD-Final | 3/18/2005 | 3/18/2005 | 3/18/2005 | P | FAIL |
Dave Hannah
|
|
|
greg; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cables for gaurds to loss 3/21/2005 2:51:10 PM
|
BLD-Final | 2/22/2005 | 2/22/2005 | 2/22/2005 | P | NR |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 2/22/2005 at 7:20:18 AM. Contact: ###-####.
|
FIRE-Final Inspection | 2/22/2005 | 2/22/2005 | 2/22/2005 | A | PASS |
Troy Cobbley
|
|
|
I signed on the fire sprinkler line on the sign off card. Other signatures already given. 2/22/2005 9:37:46 AM
|
BLD-Final | 12/16/2004 | 12/16/2004 | 12/16/2004 | P | PART |
Dave Hannah
|
|
|
Greg; Phone #: ###-#### Internet Inspection Request from: Jan Rice ok for temp occ c/n on site needs to finish shell and core permit north half and finish some mis finish items 12/16/2004 3:47:27 PM
|
BLD-Final | 12/15/2004 | 12/15/2004 | 12/15/2004 | P | NR |
Dave Hannah
|
|
|
gregg; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
FIRE-Final Inspection | 12/15/2004 | 12/15/2004 | 12/15/2004 | P | PART |
Rick Jackson
|
|
|
gregg--pending bld fn ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie Complete sprinkler in SE office 12/15/2004 4:58:42 PM
|
BLD-Conference | 12/13/2004 | 12/14/2004 | 12/14/2004 | A | PART |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 12/13/2004 at 4:30:56 PM. Contact: ###-####. walked project talked about what needed to be completed to get a temp occ 12/14/2004 11:27:01 AM
|
FIRE-Conference | 12/13/2004 | 12/14/2004 | 12/14/2004 | A | PART |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 12/13/2004 at 4:29:45 PM. Contact: ###-####. Requirements for final were reviewed with GC 12/14/2004 10:17:06 AM
|
BLD-Framing/Rough-in | 11/22/2004 | 11/23/2004 | 11/23/2004 | A | PART |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 11/22/2004 at 4:41:07 PM. Contact: ###-####. ok to start covering wall have new details for steel studs 11/23/2004 10:21:06 AM
|
BLD-Framing/Rough-in | 11/15/2004 | 11/15/2004 | 11/15/2004 | P | FAIL |
Dave Hannah
|
|
|
Greg; Phone #: ###-#### Internet Inspection Request from: Jan Rice plans call for all framing to be done in wood but crew has done it all in steel studs need new plans for arctect showing all new steel framing 11/15/2004 2:20:20 PM
|