BLD-Final | 8/8/2006 | 8/9/2006 | 8/9/2006 | A | PASS |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles OK for Perm Occ. :)
|
Code Occupancy Approval | 8/8/2006 | 8/8/2006 | 8/8/2006 | P | PASS |
Carol Montgomery
|
|
|
|
Permanent Occupancy | | 8/8/2006 | 8/8/2006 | | DONE |
|
|
|
|
BLD-Final | 4/4/2006 | 4/5/2006 | 4/5/2006 | A | PART |
Jim Sly
|
|
|
scott ; Phone #: ###-#### Internet Inspection Request from: Marsha Still OK for Temp.... OK for Perm Occ when Code Enforc Perms.
|
FIRE-Final Inspection | 4/3/2006 | 4/4/2006 | 4/4/2006 | A | PASS |
Troy Cobbley
|
|
|
Life safety finaled
|
FIRE-Final Inspection | 3/29/2006 | 3/31/2006 | 3/31/2006 | A | FAIL |
Troy Cobbley
|
|
|
Sprinkler heads need to be added in the large storage room due to a ceiling being added. Also separations have been added around the riser room that may affect sprinkler coverage.
|
FIRE-Final Inspection | 3/17/2006 | 3/20/2006 | 3/20/2006 | P | FAIL |
Troy Cobbley
|
|
|
The fire alarm permit needs finaled but when that happens the lfie safety can be finaled for this building permit.
|
FIRE-Sprinkler Rough-in | 3/10/2006 | 3/13/2006 | 3/13/2006 | A | PASS |
Troy Cobbley
|
|
|
Inspection was for the final for the fire sprinkler permit. See FIR05-00571 for entry
|
FIRE-Conference | 3/1/2006 | 3/2/2006 | 3/2/2006 | A | DONE |
Troy Cobbley
|
|
|
I had a conference with the superintendant and Treasure Valley Fire. Heads will not be required under the beam since it is only 10.5" wide but the sidewall head sprinkler deflectors exceed 6" from the beam/wall and will need to be relocated along both sides of the beams.
|
BLD-Conference | 2/24/2006 | 2/27/2006 | 2/27/2006 | A | PASS |
Jim Sly
|
|
|
Terry; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong Bldg Constr type changed from V1hr to type Vb and IIIb.
|
FIRE-Conference | 2/6/2006 | 2/7/2006 | 2/7/2006 | A | DONE |
Troy Cobbley
|
|
|
Went over life safety notes that apply to the existing church area.
|
BLD-Final | 1/13/2006 | 1/13/2006 | 1/13/2006 | P | PART |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa OK for Temp Occ Need perm from Fire and Code Enf.... Need re-insp of struct. after completion of selected areas.
|
BLD-Final | 1/6/2006 | 1/9/2006 | 1/10/2006 | P | NR |
Jim Sly
|
|
|
terry ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
FIRE-Final Inspection | 1/6/2006 | 1/9/2006 | 1/9/2006 | A | PART |
Troy Cobbley
|
|
|
A temporary occupancy was given with Dave Hanneman's permission for the church to occupy the new addition so that work can be completed in the existing area.
|
BLD-Final | 1/5/2006 | 1/6/2006 | 1/6/2006 | P | FAIL |
Jim Sly
|
|
|
terry ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie C/N Need to fire block comunication from vert to horiz in Mech and Storage rooms.
|
FIRE-Final Inspection | 1/5/2006 | 1/6/2006 | 1/6/2006 | A | FAIL |
Troy Cobbley
|
|
|
Need signage or painting of the curb when the final happens. Knox key box and occupant load signs need installed for the new addition. Per Dave Hanneman a temp is ok when fire alarm and fire sprinkler is complete in the new addition.
|
FIRE-Final Inspection | 1/4/2006 | 1/5/2006 | 1/5/2006 | P | PART |
Troy Cobbley
|
|
|
The only life safety items looked at so far are the exit signs and emergency lights in the new areas which passed except for the east corridor exit discharge light.
|
BLD-Framing/Rough-in | 12/27/2005 | 12/28/2005 | 12/28/2005 | A | PASS |
Mike Jordan
|
|
|
ceiling grid inspection//Terry; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. hallways, classrooms, kithcen, and offices.
|
BLD-Energy code compliance | 10/17/2005 | 10/18/2005 | 10/18/2005 | A | PASS |
Mike Jordan
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Also reviewed UL listings for penetrations in 3hr. cmu wall.
|
BLD-Framing/Rough-in | 10/11/2005 | 10/12/2005 | 10/12/2005 | A | PASS |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore OK to Insul....See previous notes
|
BLD-Framing/Rough-in | 10/4/2005 | 10/5/2005 | 10/5/2005 | A | PART |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Walk thru......Fireblock all dropped ceiling areas.. seal plate penitrations.... firestop all Penitrations and Constr joints in 3hr wall... Provide listed assemblies. OK to insulate.
|
BLD-Framing/Rough-in | 9/16/2005 | 9/16/2005 | 9/16/2005 | P | NR |
Tom Arcoraci
|
|
|
terry ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD-Conference | 9/13/2005 | 9/13/2005 | 9/13/2005 | P | PASS |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Walk thru with Contr
|
BLD-Conference | 9/12/2005 | 9/12/2005 | 9/12/2005 | P | CANC |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD-Conference | 8/15/2005 | 8/16/2005 | 8/16/2005 | A | DONE |
Troy Cobbley
|
|
|
Spoke to contractor about options for relocating the underground supply stub-in
|
BLD-Foundation | 5/20/2005 | 5/23/2005 | 5/23/2005 | A | PART |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore W. Wall next to existing bldg OK. 5/23/2005 9:50:57 AM
|
BLD-Footing | 5/19/2005 | 5/20/2005 | 5/20/2005 | A | PASS |
Jim Sly
|
|
|
terry ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie W. Wall by existing bldg. Epoxy dowels OKd by special insp. 5/20/2005 11:37:36 AM
|
BLD-Foundation | 5/19/2005 | 5/20/2005 | 5/20/2005 | A | PASS |
Jim Sly
|
|
|
terry ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie E. wall... next to existing. Epoxy dowels appr by special insp. 5/20/2005 11:38:39 AM
|
BLD-Foundation | 5/18/2005 | 5/18/2005 | 5/18/2005 | P | PART |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Footing at East wall next to existing bldg and completion of North wall new bldg ok. 5/18/2005 5:06:32 PM
|
BLD-Foundation | 5/16/2005 | 5/17/2005 | 5/17/2005 | P | PART |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa East, West and part of North and center walls OK. Stapley Engineering provided fix....and Terricon completed special inspection for epoxy dowels (verts) 5/17/2005 3:32:46 PM
|
BLD-Foundation | 5/13/2005 | 5/16/2005 | 5/16/2005 | A | NR |
Jim Sly
|
|
|
terry ###-#### Still waiting for Engineering Contr to fix, and special insp for any epoxy doweling. 5/16/2005 10:54:01 AM
|
BLD-Footing | 5/13/2005 | 5/13/2005 | 5/13/2005 | P | FAIL |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa #5 verticals not exposed enough above top of footing to allow for 40 diameter lap (16 to 22".... most 17") Engineer to provide fix...Do not pour. 5/16/2005 10:51:16 AM 5/16/2005 10:52:17 AM
|
BLD-Foundation | 5/12/2005 | 5/13/2005 | 5/13/2005 | P | CANC |
Jim Sly
|
|
|
TERRY; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles--cancel & reschedule
|
BLD-Footing | 5/10/2005 | 5/10/2005 | 5/10/2005 | P | PASS |
Jim Sly
|
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|