Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberBLD05-00107
StatusFinaled
Name HEATHER RICE
Site Address 3730 W QUAIL HOLLOW DR
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a five bedroom, two and half bathroom 3848 sq. ft. two story single family dwelling (2700 sq. ft. first floor/1148 sq. ft. second floor) with a attached 798 sq. ft. two car garage, a 92 sq. ft. deck off the second floor, a 92 sq. ft. covered back porch, a 194 sq. ft. covered side porch and a 300 sq. ft. covered front porch. Per approved plans, engineering and requirement list. CU94-90 per Cody Riddle with Planning and Zoning. This structure requires a fire sprinkler system installed in accordance with NFPA13D. Automatic sprinkler system flow devise shall be interconnected to sound alarm notification appliances throughout the dwelling where a fire warning system is provided. A Fire Sprinkler Permit is required prior to beginning any fire sprinkler work. This lot is within the hillside area and is subject to the hillside ordinances. A class "A" roof system and defensible space will be required. (SAM)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/13/20057/14/20057/14/2005APASS
DetailsTony Young
Scheduled by a contractor via Hello! on 7/13/2005 at 11:44:08 PM. Contact: ###-####.
DOC - Permit Finaled7/14/20057/14/20057/14/2005PPASS
DetailsTony Young
BLD-Grading Inspection7/13/20057/13/20057/13/2005 DONE
final grading and drainage approved
BLD-Energy code compliance4/12/20054/13/20054/13/2005APASS
DetailsTony Young
Heather ###-####
BLD-Framing/Rough-in4/12/20054/13/20054/13/2005APASS
DetailsTony Young
Heather ###-####
BLD-Energy code compliance4/12/20054/12/20054/12/2005PPART
DetailsTony Young
Heather ###-####
need full signoff on sprinklers,, add insulation to rim joist by front door 4/12/2005 4:52:32 PM
BLD-Final4/8/20054/12/20054/12/2005ANR
DetailsTony Young
Heather ###-####
FIRE-Final Inspection4/8/20054/11/20054/11/2005PPART
DetailsTroy Cobbley
Heather ###-#### Finish tenting in the master bedroom and in the first floor office. Master bedroom has sprinkler pendant installed too close to the fire place. There is exposed 1" CPVC pipe on top of the arch entry ot the master bedroom. Must meet requi
FIRE-Final Inspection4/8/20054/8/20054/8/2005PCANC
DetailsTroy Cobbley
heather Note: request after 3:00 pm; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Framing/Rough-in4/8/20054/8/20054/8/2005PNR
DetailsTony Young
heather Note: request after 4:00 pm; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Framing/Rough-in4/4/20054/5/20054/5/2005AFAIL
DetailsTony Young
heather ; Phone #: ###-#### Note: please call 1/2 hr prior to inspection Internet Inspection Request from: Cathy Chiles
c/n posted,,, need sprinkler sign off,,, ok to insulate walls only 4/5/2005 11:23:11 AM
BLD-Framing/Rough-in3/18/20053/18/20053/18/2005PPART
DetailsTroy James
please call prior to inspection///heather; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
pre-frame inspection and shear ok 3/18/2005 1:59:02 PM
BLD-Framing/Rough-in2/22/20052/22/20052/22/2005PPART
DetailsTony Young
retaining wall --ben ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
wip on 2' retaining wall,,, ftgs already poured 2/22/2005 2:56:06 PM
BLD-Foundation2/15/20052/15/20052/15/2005PPART
DetailsTony Young
ben; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Footing2/14/20052/14/20052/14/2005PPART
DetailsTony Young
Ben; Phone #: ###-#### Internet Inspection Request from: Jan Rice
BLD-Grading Inspection2/14/20052/14/20052/14/2005 DONE
footing subgrade approved 4 inches of loose material is removed