Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberBLD05-00495
StatusFinaled
Name BRS ARCHITECTS
Site Address 507 W HAYS ST
Project Name 
Customer Number 
ePlanReviewNo
Description
(BORCHERS) To convert the1,886 sq.ft. 1st floor of residence into office leaving the 1,697 sq.ft. 2nd floor as residential per approved plans and CUP04-00044. Work includes selective demolition done under permit BLD05-00585; reconstruction of intermediate landing on existing ramp and landing at rear door for accessibility compliance; to construct new stairs at rear door accessible landing, guards and handrails for code compliance; to reverse the swing of the rear door to provide an accessible entrance and required floor clearance's and approach clearances for accessibility; to construct interior non-bearing walls to create two fully accessible restrooms, waiting area and offices; and to resupport the existing floor system with new reinforced concrete pads, 4" x 6" columns and (2) - 1.75 x 9.5 MLB. To remodel the residential unit restroom to create two separate restrooms with new toilets, tub, shower, sinks and relocated laundry and associated plumbing and to repair the ceiling areas in the office removed to install new plumbing lines. Basement is for mechanical service to the building only. No other occupancy or use of basement allowed. All per approved plans. (drs)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/15/20059/19/20059/19/2005APASS
DetailsMike Jordan
jane; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. ok for perm occ.
Permanent Occupancy 9/19/20059/19/2005 DONE
Details
FIRE-Final Inspection9/9/20059/12/20059/12/2005PPASS
DetailsForrest France
Items on the correction notice have been amended, life safety finaled.
BLD-Other9/7/20059/7/20059/7/2005PPART
DetailsTony Young
Scheduled by a contractor via Hello! on 9/7/2005 at 7:48:27 AM.
front hand rail configuration ok,, need both sides
FIRE-Final Inspection8/11/20058/12/20058/12/2005AFAIL
DetailsTroy Cobbley
Jane, ###-#### -
Remove thumbturns from the front and back doors. Keyed is ok if meeting the requirements of review notes #13 and #14. Turn hardware around on basement access door. Provide two fire extinguishers. One upstairs and one on the main level. See review note #12. Provide verification of the cfm rating for the main level hvac unit.
BLD-Final8/10/20058/11/20058/11/2005AFAIL
DetailsTony Young
jane ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
conf. only,,, need trades 1st
BLD-Framing/Rough-in5/11/20055/12/20055/12/2005APART
DetailsTony Young
Scheduled by a contractor via Hello! on 5/11/2005 at 1:18:56 PM. Contact: ###-####.
ok to cover pending mech. permit, and approval for cover 5/12/2005 11:41:37 AM