Permit Information
Permit NumberBLD05-01602
StatusFinaled
Name WRIGHT BROTHERS THE BLDG CO
Site Address 6352 N ROE ST
Project NameThe Cottages of Boise #2
Customer Number 
ePlanReviewNo
Description
To construct a new 9,606 square feet, two story, maximum 16 residence, 14 bedroom, assisted living facility, licensed by the State of Idaho, Facility Standards. NOTE: Per signed and approved alternate letter dated 1/20/06, a maximum of 5 people will be permitted to reside in this facility which will require assistance from the staff to evacuate the building in an emergency situation and there shall always be at least one employee of the owner in this building at all times. The following items are required throughout. The installation of a NFPA 13 fire sprinkler system with quick response heads, a manual and automatic fire alarm system, a fire detection system in all areas other than the patient sleeping rooms, smoke alarms shall be installed in all sleeping rooms, incidental use separation as required by Section 302.1.1.1, an one-hour fire barrier is required between the garage and the residence and a one-hour horizontal fire assembly is required between the first and second floor . The first floor is 8,198 sq.ft with an attached 525 sq.ft. garage. The second floor is 903 sq.ft and is used for staff offices. All construction per the approved plans and attached comment list. MJP CUP04-00100 CAR 04-00036
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/30/20087/1/20087/2/2008PPASS
DetailsTony Young
Jeremy Phone #: ###-####
ok for perm c of o
BLD-Final6/16/20086/17/20086/17/2008APART
DetailsTony Young
Dan Phone #: ###-####
temp occ ok,, conf only
BLD-Final6/16/20086/16/20086/16/2008PCANC
DetailsTony Young
Dan ###-#### Inspection cancelled from web by: Alexandra Rahn
BLD-Final6/10/20086/11/20086/11/2008APART
DetailsMike Jordan
Dan Phone #: ###-####. Needs to provide sloping surface at elevation change on sog from garage to mech. room at doorway. Install remainder of smoke seals on rated doors. Noted on approved plans and plan review notes for fairhousing act for kitchen counter heights and sink depth for kitchen sink is non compliant as in installed. Plans call for 34 inch counter heights with knee clearance underneath kitchen sink and 6.5 inch max depth on portion of kitchen sink. Noted to contractor that this needs to be repaired or rebsubmit for drawings from archtiect for approval. Ok for temp occ.
FIRE-Final Inspection6/10/20086/10/20086/10/2008PPASS
DetailsTroy Cobbley
Fire life safety passed.
BLD-Aging Inspection6/5/20086/5/20086/6/2008 PASS
DetailsTony Young
BLD-Foundation3/31/20083/31/20083/31/2008PPART
DetailsTony Young
dan Phone #: ###-####
2 light pole ftgs
BLD-Footing3/27/20083/28/20083/31/2008PCANC
DetailsTony Young
dan Phone #: ###-####
BLD-Footing3/27/20083/27/20083/27/2008PFAIL
DetailsTony Young
dan Phone #: ###-####
2 light pole ftgs,, not per plan, need ok as built or redo
BLD-Other3/11/20083/12/20083/12/2008APASS
DetailsTony Young
dan Note: shear nail Phone #: ###-####
interior ok
BLD-Other3/6/20083/7/20083/7/2008APASS
DetailsTony Young
Scheduled by a contractor via Hello! on 3/6/2008 at 6:33:35 PM. Contact: ###-####.
1st layer of rock ok
BLD-Wall cover2/28/20082/29/20082/29/2008APASS
DetailsTony Young
jeremy Phone #: ###-####
BLD-Framing/Rough-in2/25/20082/26/20082/26/2008PPASS
DetailsJim Storey
dan Phone #: ###-#### c/n ok meed foire chakling/ ok to insulate.
BLD-Framing/Rough-in2/21/20082/22/20082/22/2008PPASS
DetailsTony Young
dan Phone #: ###-####
BLD-Framing/Rough-in2/21/20082/22/20082/22/2008ANR
DetailsTony Young
dan Phone #: ###-####
need trades 1st
BLD-Aging Inspection2/18/20082/18/20082/21/2008 PASS
DetailsTony Young
BLD-Framing/Rough-in12/13/200712/13/200712/13/2007PPART
DetailsTony Young
dan Phone #: ###-####
ok to rock walls where furnace is
BLD-Framing/Rough-in12/5/200712/6/200712/6/2007APART
DetailsJim Sly
dan Phone #: ###-####
OK to cover select walls in Mech Rm.
BLD-Other9/27/20079/28/20079/28/2007APASS
DetailsTony Young
jeremy Note: shear Phone #: ###-####
all ext shear ok
BLD-Footing8/22/20078/22/20078/22/2007PPART
DetailsJim Sly
bill Note: stem walls Phone #: ###-####
Stem walls OK pending MTI special inspection, tests, and approvals. Note: will provide special insp report for footing......next inspection.
BLD-Footing8/20/20078/20/20078/20/2007PPART
DetailsTony Young
Bill Phone #: ###-####-9006
pending eng/s. i. report