Permit Information
Permit NumberBLD05-01656
StatusFinaled
Name VERTICAL CONSTRUCTION
Site Address 1947 N WILDWOOD ST
Project NameSTEELWOOD FLEX CONDOS Bldg #5
Customer Number 
ePlanReviewNo
Description
(Steel Wood Flex Condos. - Building #5)(Office Shell Building) - To construct a new 22,300 square foot, one story, office shell building. This building will be constructed of masonry exterior wall, concrete slab floor and premanufactured wood trussed roof system. This building is being divided into four fire areas by three two-hour fire walls. This being done to reduce the allowable area and fire flow requirements. The areas from north to south are 6,025 sq. ft, 7,580 sq. ft., 3,740 sq. ft., 4,955 sq. ft.. This is a cold shell building permit only and no occupancy is allowed under this permit. Separate tenant improvement permits will be required to finish this building for occupancy. There is some underground utility work under this permit; however, there is no plumbing, electrical or mechanical work proposed for this part of the building project. This building will be divided into four areas separated by 8" concrete masonry interior walls. All construction per the approved plans on file. JCM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/10/20078/10/20075/5/2008PDONE
DetailsJim Sly
mark Phone #: ###-####
BLD-Final3/10/20083/11/20083/11/2008APASS
DetailsJim Sly
C/C issued
DOC - Permit Finaled3/11/20083/11/20083/11/2008PPASS
DetailsJim Sly
BLD-Final3/5/20083/6/20083/6/2008ANR
DetailsJim Sly
kim Phone #: ###-####
Need to meet at jobsite....with truss eng.
BLD-Final3/3/20083/5/20083/5/2008ANR
DetailsJim Sly
joe or kim at ###-#### Phone #: ###-####
Need to meet at jobsite with truss Eng.
BLD-Conference2/15/20082/19/20082/19/2008ADONE
DetailsJim Sly
Call Vertical and advise for final...........Talked to Kim........Need Electrical final ...(Bullit Electric) ....Verify public works signed off then call for bldg final.
BLD-Aging Inspection2/15/20082/15/20082/15/2008 PEND
DetailsJim Sly
Scheduled for 2/19/08
FIRE-Final Inspection12/5/200712/6/200712/6/2007APASS
DetailsTroy Cobbley
Fire life safety completed. KR
FIRE-Final Inspection11/29/200711/30/200711/30/2007AFAIL
DetailsTroy Cobbley
Fire hydrants are less than 40 feet from building, Let contractor know that he needs to call Dave Hanneman for approval. Also missing sign at north entrance designating fire lanes.Missing fire review notes on approved set of plans they were not on site.KR
Code Occupancy Approval8/17/20078/17/20078/17/2007PPASS
DetailsCarol Montgomery
Meets compliance with approved plans on site. Pass
BLD-Wall cover7/16/20077/16/20077/16/2007PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 7/16/2007 at 6:32:07 AM. Contact: ###-####.
OK to insulate.....still need truss eng......
BLD-Framing/Rough-in7/12/20077/13/20077/13/2007ANR
DetailsJim Sly
Internet Inspection Request from: Victoria Apatang
Need truss eng....and access to all units.
BLD-Wall cover7/12/20077/13/20077/13/2007ANR
DetailsJim Sly
Scheduled by a contractor via Hello! on 7/12/2007 at 12:14:30 PM. Contact: ###-####.
BLD-Framing/Rough-in3/19/20073/19/20073/19/2007PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 3/19/2007 at 7:38:41 AM. Contact: ###-####.
Roof deck OK
BLD-Other1/2/20071/2/20071/2/2007PPASS
DetailsTony Young
insulation on foundation//Mike Reynolds ###-####
ridgid insulation is in place on interior side of stem wall,,, for under slab
BLD-Foundation12/18/200612/19/200612/19/2006PPASS
DetailsJim Sly
Scheduled by a contractor via Hello! on 12/18/2006 at 4:26:56 PM. Contact: ###-####.
BLD-Footing12/11/200612/12/200612/12/2006APASS
DetailsJim Sly
Scheduled by a contractor via Hello! on 12/11/2006 at 3:55:42 PM. Contact: ###-####.
Verified U-FER ground .....measuring at least 20' ......Insulation removed, and wire @ 250 KC Mill Footing OK.