Permit Information
Permit NumberBLD05-01956
StatusFinaled
Name PACIFIC SUBS
Site Address 509 W MAIN ST
Project NamePACIFIC SUBS
Customer Number 
ePlanReviewNo
Description
(PACIFIC SUBS) Remodel to an existing vacant tenant space changing occupancy for a new 3,408 sq. ft. assembly restaurant tenant in an existing 9,600 sq. ft. building per approved plans. Work to include some rated CMU wall infill in some existing openings in the west exterior wall and one in the south exterior wall, new interior 2-hour rated fire barrier walls to reduce the fire area and to act as a horizontal exit, a new pair of 90 minute rated doors in the 2-hour rated fire barrier/horizontal exit, new interior walls and doors, interior finish, casework and kitchen equipment, two new accessible restrooms, mechanical work, plumbing work, and electrical work. There is a combination of Separated and Nonseparated Uses within this building. A Certificate of Occupancy is to be issued when completed and approved. NOTE: This building is not fire sprinklered. JCB
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/18/200511/23/200511/23/2005PPASS
DetailsTom Arcoraci
ryan ; Phone #: ###-####//please check if mechanical permit needed for this project// Internet Inspection Request from: Marsha mech permit not required non done
FIRE-Final Inspection11/22/200511/23/200511/23/2005APASS
DetailsForrest France
c/n items have been completed, life safety passed.
Permanent Occupancy 11/23/200511/23/2005 DONE
Details
FIRE-Final Inspection11/22/200511/22/200511/22/2005PNR
DetailsForrest France
c/n not 100% completed yet per contractor.
FIRE-Final Inspection11/18/200511/22/200511/22/2005ANR
DetailsForrest France
Per contractor phone call, not all items on the correction notice have been completed.
FIRE-Final Inspection11/17/200511/18/200511/18/2005AFAIL
DetailsForrest France
Remove surface bolts and door stopper at back double doors, lower the provided fire ext. to 48" max AFF,one bulb at emergency light is out, provide visual indicator at main entry/exit door, post max occupant sign, no storage allowed in the break room, duct smoke detectors may be required at AHU's.
BLD-Final11/17/200511/18/200511/18/2005PCANC
DetailsDave Hannah
ryan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Inspection cancelled from web by: Marsha Smylie
BLD-Framing/Rough-in11/8/200511/9/200511/9/2005APART
DetailsDave Hannah
lloyd; Phone #: ###-#### Note: please call 1/2 hr prior to inpspection Internet Inspection Request from: Cathy Chiles 2hr wall sep in attic ok to install ceiling
BLD-Framing/Rough-in10/24/200510/25/200510/25/2005AFAIL
DetailsJim Storey
lloyd; Phone #: ###-#### Note: please call 1/2 hr prior to inspection Internet Inspection Request from: Cathy Chiles