Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD05-02489
StatusFinaled
Name HILBERS INC
Site Address 1666 S ENTERTAINMENT AVE
Project NameFUDDRUCKERS RESTAURANT
Customer Number 
ePlanReviewNo
Description
(Fuddruckers Restaurant) To construct a 7,841 sq. ft. one story Type VB fully fire sprinkled restaurant. Other work includes all site improvements, paving and landscaping per approved plans and attachments, DR05-0233. Fire sprinklers used for area
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Code Occupancy Approval7/19/20077/19/20077/19/2007PPASS
DetailsScott M.Brown
finaly planted replacement trees final signed off
BLD-Final7/19/20077/19/20077/19/2007PPASS
DetailsMike Jordan
Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. ok for perm occ.
BLD-Final8/28/20068/28/20068/28/2006PNR
DetailsMike Jordan
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Still needs to bond for trees that have been removed, Still needs final from CDHD. Contacted contractor (Jack) to inform him that thr temp. occ. expires this Saturday and either needs to resolve issues or request an extension. Jack noted that he wuold contact the owner and inform him of issues.
BLD-Conference7/7/20067/7/20067/10/2006ADONE
DetailsMike Jordan
Met with fire dept. to go over issues from compliant. Contacted contractor and left message.
Code Occupancy Approval  6/6/2006 FAIL
THEY CUT AND REMOVED 3 MATURE TREES. THEY MUST BOND FOR THE TREES.
FIRE-Final Inspection6/5/20066/6/20066/5/2006APASS
DetailsTroy Cobbley
Life safety finaled
FIRE-Final Inspection6/2/20066/2/20066/2/2006PPART
DetailsTroy Cobbley
A temporary occupancy was given with Dave Hannimans permission until the correct covers are installed on the a/v's in the outdoor area. Life safety is ok to final when fire alarm is finaled.
FIRE-Final Inspection5/26/20065/30/20065/30/2006AFAIL
DetailsTroy Cobbley
Fire alarm permit needs to be finaled. When that is done then life safety can be signed off.
FIRE-Final Inspection5/25/20065/26/20065/26/2006AFAIL
DetailsForrest France
The project related fire sprinkler and alarm permits must be inspected and approved prior to life safety final approval. Informed general contractor of requirements and advised him to read the building permit fire code review notes and pretest before next inspection.
BLD-Final5/25/20065/26/20065/26/2006PPART
DetailsMike Jordan
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. ok for temp occ if fire,life/safety signs. Also needs to install boots under sinks in bathrooms, grab bars not per plan.
Code Occupancy Approval Temp5/25/20065/25/20065/25/2006PDONE
DetailsScott M.Brown
SOME SMALL AMOUNT OF TRIM AND LANDSCAPE TO FINISH. I SIGNED TEMP OCCUPANCY DUE TO LOW DOLLAR AMOUNT TO BOND NOT MAKING THEM BOND.
BLD-Other5/24/20065/24/20065/24/2006PFAIL
DetailsMike Jordan
jack Note: t-bar; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Ceiling grid not per plan. Need letter from arch. or change grid so it is per plan.
BLD-Framing/Rough-in4/10/20064/11/20064/11/2006APASS
DetailsMike Jordan
Jack; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
BLD-Energy code compliance4/7/20064/10/20064/10/2006APASS
DetailsMike Jordan
Jack; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Perimeter walls.
BLD-Framing/Rough-in3/31/20064/3/20064/3/2006PPART
DetailsMike Jordan
jack; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. framing on perimeter walls only. Verifiied all holdowns per plan. verified straps for beam to beam connections. Also inspected nailing on interior shear walls.
BLD-Framing/Rough-in3/27/20063/28/20063/28/2006PPART
DetailsMike Jordan
Jack -- roof nail inspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Roof insp. All missing hardware gas been installed. ok to cover roof. Contractor to supply RFI regarding placement of some straps.
BLD-Framing/Rough-in3/20/20063/21/20063/21/2006PFAIL
DetailsMike Jordan
Jack -- roof nail inspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Noted several areas were straps were not installed. Roof not ok to cover.
BLD-Framing/Rough-in3/14/20063/14/20063/14/2006PPART
DetailsMike Jordan
Jack -- shear wall; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Shear nailing on exterior walls only.
FIRE-Conference3/3/20063/6/20063/6/2006PDONE
DetailsTroy Cobbley
Jack; Phone #: ###-#### I went over manual pull station locations for the hood suppression system with Jack. They need to be located 10' to 20' away and between 4' and 5' AFF.
BLD-Footing1/11/20061/12/20061/12/2006PPART
DetailsMike Jordan
request early pm//jack; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. All reinforcement in place, perimeter footings and interior column pads. Noted several areas with insufficient clearances, special inspector to verify prior to placement of concrete. wip
BLD-Conference1/9/20061/10/20061/10/2006ADONE
DetailsMike Jordan
###-#### - jack. Contractor questioned standing water in bottom of footings. Noted to contractor that water needs to be removed by pumping it out. Special inspector to verify bottom of footing condition.