BLD-Final | 10/16/2009 | 10/19/2009 | 10/19/2009 | A | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
DOC - Permit Finaled | 10/19/2009 | 10/19/2009 | 10/19/2009 | P | PASS |
Mike Jordan
|
|
|
Letter of compliance issued. Shell and core only. No slab on grade or other trades on interior work. Also noted on approved plans that remainder of 1hr. rated const. to be completed when TI work is to start. Still need rated const. at ceiling and for 10ft. on exterior wall from property line at tenant seperation. Elec. panel will be and issue.
|
FIRE-Final Inspection | 10/15/2009 | 10/16/2009 | 10/16/2009 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed.
|
BLD-Conference | 10/14/2009 | 10/14/2009 | 10/14/2009 | P | PASS |
Mike Jordan
|
|
|
Spoke to cameron with Jayo const. Noted to him to get life/safety and bldg. finals for shell and core. all other trades and zoning have signed off. Cameron noted that he would get plans and get the life/safety and shell and core finaled so that permit can be closed out and not expired.
|
BLD-Final | 5/20/2008 | 5/21/2008 | 5/21/2008 | P | NR |
Mike Jordan
|
|
|
Cameron; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. Needs life/safety final.
|
Code Occupancy Approval | 3/10/2008 | 3/10/2008 | 3/10/2008 | P | PASS |
Scott M.Brown
|
|
|
OK FOR FINAL
|
BLD-Conference | 2/25/2008 | 2/25/2008 | 2/25/2008 | P | PASS |
Mike Jordan
|
|
|
Called and spoke to Kameron Jayo, He noted that he would get all finals called in so that permit could be sighned off.
|
BLD-Framing/Rough-in | 11/2/2006 | 11/2/2006 | 11/2/2006 | P | NR |
Mike Jordan
|
|
|
jeff ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
|
BLD-Framing/Rough-in | 11/1/2006 | 11/1/2006 | 11/1/2006 | P | FAIL |
Mike Jordan
|
|
|
jeff; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. NOted elec. panel in 1 hr exterior wall, must be moved or boxed out.
|
BLD-Framing/Rough-in | 10/27/2006 | 10/30/2006 | 10/30/2006 | A | NR |
Mike Jordan
|
|
|
kameron; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs elec. ri insp. Elec permit attached is for the tenant improvement and not the shell.
|
BLD-Wall cover | 7/20/2006 | 7/20/2006 | 7/20/2006 | P | PART |
Mike Jordan
|
|
|
Noted that remainder of inspections were completed along with bldg F (bld06-00169) noted on posted c/n that contractor needs to call in both permits for insp. Roof nailing and hardware ok. Exterior shear wall nailing ok. Simpson holddown straps not installed. c/n posted. ok to cover roof.
|
BLD-Footing | 6/2/2006 | 6/5/2006 | 6/5/2006 | A | PART |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Permiter footings. Contractor to confirm special insp.
|