BLD-Final | 2/28/2007 | 3/1/2007 | 3/1/2007 | A | PASS |
Mike Jordan
|
|
|
adem; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
DOC - Permit Finaled | 3/1/2007 | 3/1/2007 | 3/1/2007 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Energy code compliance | 10/12/2006 | 10/12/2006 | 10/12/2006 | P | DONE |
Mike Jordan
|
|
|
aden; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. This insp. was done yesterday.
|
BLD-Energy code compliance | 10/11/2006 | 10/11/2006 | 10/11/2006 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
|
BLD-Framing/Rough-in | 10/9/2006 | 10/10/2006 | 10/10/2006 | A | NR |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Patricia Sm. wip.
|
BLD-Framing/Rough-in | 10/5/2006 | 10/5/2006 | 10/5/2006 | P | PASS |
Mike Jordan
|
|
|
Adam; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. All framing issues have been resolv ed. ok to insul.
|
BLD-Framing/Rough-in | 10/2/2006 | 10/2/2006 | 10/2/2006 | P | FAIL |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs to complete repair of D4 truss as per truss engineering. Riser on stairs vary greater than the 3/8 inch allowed. Egress windows upstairs exceed the 42 inch max height. c/n posted. All other framing issues have been resolved. ok to insul.
|
BLD-Framing/Rough-in | 9/15/2006 | 9/15/2006 | 9/15/2006 | P | DONE |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. THIS WAS A CONFERANCE. Met with contractor on site and went over c/n notice. Some additional corrections were added. Needs to repair stair way, walking surface was sloped to much, Needs to remove window from bathroom to garage. Add blocking and studs to rimjoist at 3ply girder truss. add strap at top plate in garage and remove closet from mech. room and get engineered fix for D4 truss. Add trimmers at 3ply truss in garage.
|
BLD-Framing/Rough-in | 9/13/2006 | 9/13/2006 | 9/13/2006 | P | FAIL |
Mike Jordan
|
|
|
Adam; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. Complete lateral bracing. Tbe required at 3ply girder truss in garage. Fireblock mech. chase and all furouts. c/n posted. do not insul.
|
BLD-Framing/Rough-in | 9/12/2006 | 9/13/2006 | 9/13/2006 | A | NR |
Mike Jordan
|
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs to provide an approved set of plans for framing insp. c/n posted.
|
BLD-Footing | 5/17/2006 | 5/18/2006 | 5/18/2006 | A | PART |
Mike Jordan
|
|
|
RICK ###-####. early start,
|