Code Occupancy Approval | | | 1/19/2007 | | PASS |
|
|
|
WILL SIGN PERM OCCUPANCY GRASS IN NOW.
|
Permanent Occupancy | | 1/12/2007 | 1/12/2007 | | DONE |
|
|
|
|
BLD-Final | 12/21/2006 | 12/22/2006 | 12/22/2006 | A | PART |
Jim Sly
|
|
|
keith; Phone #: ###-#### Internet Inspection Request from: Sherri Bennett OK for Temp Occ. OK for Perm Occ when Zoning/Code enforce signs off Perm.
|
BLD-Final | 12/20/2006 | 12/21/2006 | 12/21/2006 | P | CANC |
Mike Jordan
|
|
|
keith ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith. Canc. by contractor. Waiting for code enforcement.
|
Code Occupancy Approval Temp | | | 12/21/2006 | | DONE |
|
|
|
I SIGNED TEMP ONLY DUE TO SOME SOD NEEDS PLACED, WILL RECHECK NEXT WEEK, AND IF NOT IN WILL REQUIRE BOND.
|
FIRE-Final Inspection | 12/13/2006 | 12/14/2006 | 12/14/2006 | A | PASS |
Troy Cobbley
|
|
|
Permit finaled
|
BLD-Energy code compliance | 10/24/2006 | 10/24/2006 | 10/24/2006 | P | CANC |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 10/24/2006 at 8:54:26 AM. Contact: ###-####.
|
BLD-Framing/Rough-in | 10/24/2006 | 10/24/2006 | 10/24/2006 | P | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 10/24/2006 at 8:54:26 AM. Contact: ###-####. Inspected 5/8ype X at soffitt and can lights.
|
FIRE-Final Inspection | 10/23/2006 | 10/23/2006 | 10/23/2006 | P | NR |
Forrest France
|
|
|
Project is not ready for life safety final inspection.
|
BLD-Energy code compliance | 10/16/2006 | 10/17/2006 | 10/17/2006 | A | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 10/16/2006 at 2:47:54 PM. Contact: ###-####. All framing issues have been resolved.
|
BLD-Framing/Rough-in | 10/9/2006 | 10/10/2006 | 10/10/2006 | A | PART |
Mike Jordan
|
|
|
Framers to check nailing on east wall. Needs to firecaulk elec. penetrations at soffitt at camnlights. Also needs to replace some 5/8 type x at soffitt that was damaged. Provide truss fix. ok to insul.
|
BLD-Framing/Rough-in | 10/6/2006 | 10/9/2006 | 10/9/2006 | P | NR |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 10/6/2006 at 3:05:10 PM. Contact: ###-####. Elec ri insap. failed.
|
BLD-Framing/Rough-in | 9/26/2006 | 9/26/2006 | 9/26/2006 | P | PART |
Mike Jordan
|
|
|
keith; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Roof shearnailing only. Still needs to doublerock soffit and box out can lights.
|
BLD-Other | 8/22/2006 | 8/23/2006 | 8/23/2006 | A | PART |
Mike Jordan
|
|
|
steve Note: stem wall; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Footing | 8/22/2006 | 8/22/2006 | 8/22/2006 | P | PART |
Mike Jordan
|
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Perimeter footing.
|