Permit Information
Permit NumberBLD07-00494
StatusFinaled
Name STAN'S CHARBROILED NY HOTDOGS
Site Address 818 S VISTA AVE
Project NameVISTA VILLAGE-PHASE II
Customer Number 
ePlanReviewNo
Description
(STAN'S CHARBROILED N.Y. HOTDOGS - VISTA VILLAGE - NORTH ADDITION) This building is fire sprinklered for fire area and for building area increase. To create a 1,913 square foot restaurant within an 8,260 square foot, one story building. This tenant space is located within a new addition constructed under permit BLD04-02464. Work is to include 2 restrooms accessible to the disabled, 2 grease hoods and ducts, interior nonbearing walls, suspended ceilings, and finishes. In addition, an existing wall will be fully upgraded to comply as a 3-hr fire wall. Work is to include altering an existing masonry wall to comply as a 3-hr fire-resistance-rated wall assembly, protecting openings in the fire wall with fire assemblies having a 3-hr fire protection rating, constructing a 3-hr fire-resistance-rated gypsum board wall assembly through the concealed area of an existing canopy, and ensuring a 1-hr fire-resistance-rating for the exterior wall behind and below the canopy for a distance not less than the depth of the canopy on both sides of the fire wall. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection10/12/200710/12/200710/12/2007PPASS
DetailsForrest France
Fire life safety finaled.
BLD-Final10/11/200710/12/200710/12/2007APASS
DetailsJim Storey
todd Phone #: ###-####
BLD-Final10/10/200710/10/200710/10/2007PNR
DetailsJim Storey
todd Phone #: ###-#### need fire 07-00799/mec 07-02837
FIRE-Final Inspection10/1/200710/1/200710/1/2007PFAIL
DetailsForrest France
Need project related fire alarm and hood suppression system permits finaled prior to life safety approval.
FIRE-Final Inspection9/28/200710/1/200710/1/2007ACANC
DetailsForrest France
###-#### - mike Note: hood final Not ready for inspection per phone call from contractor due to electrical issues.
BLD-Other9/26/200710/1/200710/1/2007ACANC
DetailsJim Storey
mike - hood inspection Phone #: ###-#### should be fire
BLD-Other9/26/20079/27/20079/27/2007APASS
DetailsJim Storey
Todd this inspection is for the celing Phone #: ###-####
BLD-Framing/Rough-in9/26/20079/27/20079/27/2007APART
DetailsJim Storey
Todd Phone #: ###-####
BLD-Other9/25/20079/26/20079/26/2007ADEFR
DetailsJim Storey
mike - kitchen hood Phone #: ###-#### fire requist.
BLD-Aging Inspection8/24/20078/24/20078/31/2007 NR
DetailsJim Storey
ncfi