BLD-Final | 12/26/2007 | 12/26/2007 | 12/26/2007 | A | PASS |
Tom Arcoraci
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton
|
FIRE-Final Inspection | 12/26/2007 | 12/26/2007 | 12/26/2007 | A | PASS |
Troy Cobbley
|
|
|
All repairs corrected per Troys notes. KR
|
BLD-Final | 12/21/2007 | 12/21/2007 | 12/21/2007 | P | CANC |
Mike Jordan
|
|
|
paul Phone #: ###-####
|
FIRE-Final Inspection | 12/20/2007 | 12/21/2007 | 12/21/2007 | A | FAIL |
Troy Cobbley
|
|
|
Out of the total 56 doors, of the 6 doors that I tried, only 2 closed/latched completely. One of the general contractors workers became ignorant with me so I stopped the inspection and left. I notified jennifer.
|
Code Occupancy Approval | 12/20/2007 | 12/20/2007 | 12/20/2007 | P | PASS |
Scott M.Brown
|
|
|
OK FOR FINAL
|
FIRE-Final Inspection | 12/19/2007 | 12/20/2007 | 12/20/2007 | A | FAIL |
Troy Cobbley
|
|
|
Provide self closers on all doors in the fire rated wall.
|
FIRE-Final Inspection | 12/14/2007 | 12/14/2007 | 12/14/2007 | P | FAIL |
Troy Cobbley
|
|
|
The project related fire sprinkler and fire alarm need to be finaled first. I let paul know that self closing doors are required. This was verified with Tim in plan review. A knox key box is being worked out as well.
|
BLD-Conference | 11/6/2007 | 11/6/2007 | 11/6/2007 | A | DONE |
Mike Jordan
|
|
|
i will be there until 8:30 Phone #: ###-#### Internet Inspection Request from: paul thornton
|
BLD-Conference | 10/30/2007 | 10/30/2007 | 10/30/2007 | A | DONE |
Mike Jordan
|
|
|
the installer will be there around 9:30 Phone #: ###-#### Internet Inspection Request from: paul thornton
|
BLD-Conference | 10/26/2007 | 10/26/2007 | 10/26/2007 | P | CANC |
Mike Jordan
|
|
|
paul Phone #: ###-####. Will reshedule.
|
BLD-Conference | 10/10/2007 | 10/10/2007 | 10/10/2007 | A | DONE |
Mike Jordan
|
|
|
the earlier the better Phone #: ###-#### Internet Inspection Request from: paul thornton
|
BLD-Wall cover | 9/28/2007 | 9/28/2007 | 9/28/2007 | P | PASS |
Mike Jordan
|
|
|
hat channel and 1st and 2nd layers of 5/8 type x at 1hr walls ans floor ceiling assemblies.
|
BLD-Energy code compliance | 9/26/2007 | 9/26/2007 | 9/26/2007 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton. B vent has UL listed collar, all fire stop/block is complete. ok to cover.
|
BLD-Framing/Rough-in | 9/20/2007 | 9/21/2007 | 9/21/2007 | A | PART |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton. pend. fire insp. Will check remaining issues on energy.
|
BLD-Framing/Rough-in | 9/19/2007 | 9/19/2007 | 9/19/2007 | A | PART |
Mike Jordan
|
|
|
Phone #: ###-#### Internet Inspection Request from: paul thornton. Complete firestop at sprinkler line penetrations, and floor ceiling penetrations, provide approved UL listed collar assembly for B vent at floor ceiling penetration. Complete lateral bracing, provide putty pads on elec. boxes were needed. repair tub drain penetration. pending fire ri insp. c/n posted.
|
BLD-Conference | 8/13/2007 | 8/13/2007 | 8/13/2007 | P | DONE |
Mike Jordan
|
|
|
paul Phone #: ###-####
|
BLD-Other | 8/6/2007 | 8/6/2007 | 8/6/2007 | P | PART |
Mike Jordan
|
|
|
paul Note: shear Phone #: ###-####. 5/8 type X, exterior portion of 1hr assembly ok.
|
BLD-Wall cover | 8/3/2007 | 8/3/2007 | 8/3/2007 | P | PART |
Mike Jordan
|
|
|
Exterior shear nailing and holdowns.
|
BLD-Conference | 8/2/2007 | 8/3/2007 | 8/3/2007 | A | CANC |
Mike Jordan
|
|
|
i want to sheetrock exterior to start siding Phone #: ###-#### Internet Inspection Request from: paul thornton. rescheduled for this afternoon.
|
BLD-Footing | 7/13/2007 | 7/13/2007 | 7/13/2007 | P | PASS |
Jim Sly
|
|
|
paul Phone #: ###-#### Interior footings
|
BLD-Other | 6/26/2007 | 6/27/2007 | 6/27/2007 | A | PART |
Mike Jordan
|
|
|
a look at the blueboard Phone #: ###-#### Internet Inspection Request from: paul thornton. rigid foam insul. at interior side of stemwall.
|
BLD-Foundation | 6/22/2007 | 6/22/2007 | 6/22/2007 | P | PASS |
Mike Jordan
|
|
|
matt; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
|
BLD-Footing | 6/21/2007 | 6/21/2007 | 6/21/2007 | P | PASS |
Mike Jordan
|
|
|
matt; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
|