Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD07-00608
StatusFinaled
Name S & D DEVELOPMENT INC
Site Address 10093 W RIFLEMAN LN
Project NameEverett Estates 4-plex
Customer Number 
ePlanReviewNo
Description
(EVERETT ESTATES LOT 5) To construct a new 3,982 square feet, two story, four unit apartment building. The first floor is 2,076 square feet the second floor is 1,906 square feet. Each unit is two bedrooms, one bath at 884 square feet with a 40 square feet covered patio. NOTE: The installation of a NFPA 13-R fire sprinkler system is required because of fire department vehicle access. All construction shall be per the approved plans and attached comment list. MJP DRH 07-00082 CUP05-00056Y
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/26/200712/26/200712/26/2007APASS
DetailsTom Arcoraci
Phone #: ###-#### Internet Inspection Request from: paul thornton
FIRE-Final Inspection12/26/200712/26/200712/26/2007APASS
DetailsTroy Cobbley
All repairs corrected per Troys notes. KR
BLD-Final12/21/200712/21/200712/21/2007PCANC
DetailsMike Jordan
paul Phone #: ###-####
FIRE-Final Inspection12/20/200712/21/200712/21/2007AFAIL
DetailsTroy Cobbley
Out of the total 56 doors, of the 6 doors that I tried, only 2 closed/latched completely. One of the general contractors workers became ignorant with me so I stopped the inspection and left. I notified jennifer.
Code Occupancy Approval12/20/200712/20/200712/20/2007PPASS
DetailsScott M.Brown
OK FOR FINAL
FIRE-Final Inspection12/19/200712/20/200712/20/2007AFAIL
DetailsTroy Cobbley
Provide self closers on all doors in the fire rated wall.
BLD-Energy code compliance10/5/200710/5/200710/5/2007PPASS
DetailsJim Sly
BLD-Framing/Rough-in10/4/200710/5/200710/5/2007PCANC
DetailsMike Jordan
Phone #: ###-#### Internet Inspection Request from: paul thornton
BLD-Framing/Rough-in10/2/200710/2/200710/2/2007APART
DetailsMike Jordan
Phone #: ###-#### Internet Inspection Request from: paul thornton. Needs to complete firestopping- sprinkler lines and all floor penetrations. Provide squash blocking and additional studs to carry point load from above at lower unit east side, front bedroom. c/n posted. ok to insul.
BLD-Other8/8/20078/8/20078/8/2007APART
DetailsMike Jordan
paul - ###-#### - shear . Exterior shear only.
BLD-Other6/27/20076/27/20076/27/2007PPART
DetailsMike Jordan
paul - look at blue board for inspection Phone #: ###-####. Rigid foam insul.
BLD-Other6/26/20076/27/20076/27/2007APART
DetailsMike Jordan
a look at the blueboard Phone #: ###-#### Internet Inspection Request from: paul thornton. rigid foam insul at stemwall.
BLD-Foundation6/19/20076/20/20076/20/2007PPART
DetailsMike Jordan
matt; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
BLD-Footing6/18/20076/19/20076/19/2007PPASS
DetailsMike Jordan
matt; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang