Permit Information
Permit NumberBLD07-00712
StatusFinaled
Name JAMES W ELMER CONSTRUCTION
Site Address 8300 W EMERALD ST
Project NameREI
Customer Number 
ePlanReviewNo
Description
**(REI)** To remodel the interior and exterior of an existing 25123 sq ft retail tenant store per approved plans & DRH07-00192. Work to include, construction of a new storefront, removal of interior partitions, counters, plumbing fixtures and miscellaneous finishes, remodel the entire retail showroom area, remove existing racking A SEPARATE PERMIT WILL BE REQUIRED for any additional new racking systems that are over eight feet in height, construction of a new trash enclosure, all new restroom fixtures and finishes, installation of all new lighting, miscellaneous related interior finishes. This building is fully fire sprinkled any alterations or modifications to the sprinkler system shall be maintained and installed per NFPA #13 as regulated by the fire department. RmH
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/6/20083/7/20083/7/2008APASS
DetailsMike Jordan
terry Phone #: ###-####
DOC - Permit Finaled3/7/20083/7/20083/7/2008PPASS
DetailsMike Jordan
All issues have been resolved, double leaf doors are now code compliant. Letter of comliance was issued verified all signatures. Contractor to fax final letter from special insp. agency.
FIRE-Final Inspection3/6/20083/6/20083/7/2008PPASS
DetailsTroy Cobbley
Life safety passed.
FIRE-Final Inspection11/20/200711/21/200711/21/2007AFAIL
DetailsTroy Cobbley
Repair exit signs, provide emergency lights in the stockroom, provide exit sign at the main exit and provide approved hardware at the main exit.
BLD-Final11/20/200711/20/200711/20/2007PNR
DetailsMike Jordan
jake Phone #: ###-####
BLD-Framing/Rough-in10/30/200710/30/200710/30/2007PPASS
DetailsMike Jordan
jake Phone #: ###-####
BLD-Framing/Rough-in10/19/200710/19/200710/19/2007PPASS
DetailsMike Jordan
jake Phone #: ###-####. Recieved and reviewed special insp. reports as well as a letter from engineer of record stating that majority of criteria set forth has been met and that inspections have met the specifications as set forth on sheet S1.0 of the approved plans. Also performed framing inspection of steel studs for new store front. Noted that all bracing for parapet to existing roof is not yet complete. Gave contractor ok to resume work and to make certain to get remainder of special insp. Also noted that contractor is going to replace double leaf door to make it code compliant.
BLD-Conference10/18/200710/18/200710/18/2007AFAIL
DetailsMike Jordan
Met on site with contractor and specail inspector. Also recieved copy of letter from engineer of record of the inspection requirements that need to be completed. Also issued a written c/n to contractor regarding the locks on doulble leaf door.
BLD-Conference10/15/200710/15/200710/15/2007AFAIL
DetailsMike Jordan
Spoke with with structural engineer of record to inform him of the lack of structural inspections on new store front. Noted to engineer that letter from him acceptinf all in place work to date would be required prior to allowing the contractor to continue work on store front. Contractor to get all special inspections necessary and other other inspections necessary to fullfill structural enginneers requirements so that acceptance letter can be issued. Also noted that new double leaf doors installed at main enterance needs to have a lock indicator installed and automatic flush bolt, the seperate lock on the opposite leaf must be removed.
BLD-Conference10/12/200710/12/200710/12/2007PFAIL
DetailsMike Jordan
Noted no inspection done on framing or footings to date from Boise City or special insp. agency. Issued a c/n notice to super on site (Jake) stating to stop work on store front, hire special insp. agency and contact structural engineer of record. A meeting is to be set up with Boise city Inspector, special insp. agency, contractor and engineer before further work can resume.