Permit Information
Permit NumberBLD07-00735
StatusFinaled
Name BRIGHTON PROPERTIES LLC
Site Address 2817 S FEATHERLY WAY
Project NameVIC PARK BUILDING #4
Customer Number 
ePlanReviewNo
Description
Vic Park Building #4- (Shell) - To construct a new 32,350 square foot, one story, shell building and related site improvements. This building will be constructed of concrete slab floor, concrete tilt-up exterior walls and steel joist roof system. There will be a 130 square foot Mechanical/Electrical Room constructed under this permit. This is a shell permit only and no occupancy is allowed under this permit. Separate tenant improvment permit will be required to finish this building for occupancy. All construction per the approved plans and attached comment list. JCM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/28/200711/29/200711/29/2007APASS
DetailsMike Jordan
DARIN Phone #: ###-####
DOC - Permit Finaled11/29/200711/29/200711/29/2007PPASS
DetailsMike Jordan
Letter of compliance issued, verified all signatures.
Code Occupancy Approval11/28/200711/28/200711/28/2007PPASS
DetailsScott M.Brown
OK FOR FINAL
FIRE-Final Inspection11/27/200711/27/200711/27/2007PPASS
DetailsTroy Cobbley
Life safety passed
FIRE-Final Inspection11/26/200711/26/200711/26/2007PFAIL
DetailsTroy Cobbley
The exit discharge lighting needs to be repaired.
BLD-Final11/19/200711/20/200711/20/2007ACANC
DetailsMike Jordan
Darren Phone #: ###-####. canc. by contractor.
BLD-Final10/16/200710/17/200710/17/2007ACANC
DetailsMike Jordan
DARIN nOTE: PLEASE CALL 1/2 HR PRIOR TO INSPECTION Phone #: ###-####
BLD-Framing/Rough-in10/17/200710/17/200710/17/2007APASS
DetailsMike Jordan
DARIN nOTE: PLEASE CALL 1/2 HR PRIOR TO INSPECTION Phone #: ###-####. Steel framing for mech/riser room and soffits for store fronts. ok.
BLD-Conference9/26/20079/27/20079/27/2007ADONE
DetailsMike Jordan
darren - please call 1/2 hr prior to inspection Phone #: ###-####
BLD-Other8/16/20078/17/20078/17/2007APART
DetailsMike Jordan
darin Note: rebar Phone #: ###-####. Reinforcement for conc. tilt panels #9-17
BLD-Footing7/18/20077/19/20077/19/2007PPART
DetailsMike Jordan
darren; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang. wip. East, west and south perimeter footings.
BLD-Other7/11/20077/12/20077/12/2007PPART
DetailsMike Jordan
DARIN NOTE: REBAR Phone #: ###-####wip. Reinforcement for concrete tilt panels 1-8 and 18-33.
BLD-Footing6/19/20076/20/20076/21/2007PPART
DetailsMike Jordan
darren; Phone #: ###-#### Internet Inspection Request from: Victoria Apatangwip. Project is recieving special insp.