Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD07-00772
StatusFinaled
Name THE RETAIL REPAIR SHOP
Site Address 925 N MILWAUKEE ST
Project NameAMERISUITES
Customer Number 
ePlanReviewNo
Description
(AMERISUITES - LOBBY REMODEL) To remodel the first floor entry lobby area, enlarge the dining area and renovating an existing suite and convert it to the prep kitchen. NOTE: This building is fully fire sprinklered with a NFPA 13 system and is used for area increase. All construction shall be per the approved plans and attached comment list. MJP
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/17/200712/17/200712/17/2007PPASS
DetailsMike Jordan
robert Phone #: ###-####
DOC - Permit Finaled12/17/200712/17/200712/17/2007PPASS
DetailsMike Jordan
Letter of compliance issued. Reinspected ceiling grid ok. Also reviewed final letter from special insp. agency. One item noted, no welder certs. Contractor did have a copy of welder certs, all were up to date. Noted that roll up door was deleted, no door was placed at pass thru room. After meeting with Jim Story on job site, it was decided that this one hr. wall could be moved back to east side of kitchen and make that the rated corridor wall. Also recieved revised drawing from architect noted the changes.
BLD-Final12/17/200712/17/200712/17/2007PCANC
DetailsMike Jordan
FIRE-Final Inspection12/14/200712/17/200712/17/2007APASS
DetailsTroy Cobbley
fire life safety passed
BLD-Final12/14/200712/17/200712/17/2007ACANC
DetailsMike Jordan
Robert; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
BLD-Final12/13/200712/14/200712/14/2007PNR
DetailsMike Jordan
robert Phone #: ###-####. Needs life/safety.
BLD-Other12/11/200712/12/200712/12/2007PFAIL
DetailsMike Jordan
Robert This inspection is for t-bar Phone #: ###-####. Needs to remove pop rivets and repair wire to meet the 1:6.
BLD-Framing/Rough-in11/30/200711/30/200711/30/2007PPART
DetailsMike Jordan
bryan Phone #: ###-####. Fur out wall in main lobby area only.
BLD-Framing/Rough-in11/26/200711/27/200711/27/2007APART
DetailsMike Jordan
john Phone #: ###-####. Still need UL tech data for wonder board on 1hr wall assembly, Noted that roll down firedoor needs to be side hinged to meet egress.
BLD-Final11/23/200711/26/200711/26/2007PPART
DetailsMike Jordan
John Phone #: ###-####. ok to use lobby area only. Putty pads installed on new 1hr wall. ok to cover.
FIRE-Final Inspection11/23/200711/26/200711/26/2007APART
DetailsTroy Cobbley
See the city approved for the lobby location, circled with yellow hilighter, that is ok to occupy. It has also been signed with todays date.
BLD-Final11/20/200711/21/200711/21/2007PCANC
DetailsMike Jordan
jon - partial final Phone #: ###-####
BLD-Framing/Rough-in11/21/200711/21/200711/21/2007PPART
DetailsMike Jordan
jon - partial final Phone #: ###-####. 1hr. wall. ok to one side only.
FIRE-Final Inspection11/20/200711/21/200711/21/2007AFAIL
DetailsTroy Cobbley
The contractor wanted a partial fire life safety for the remodeled area of the main lobby. I found emergency lights not operating, sprinkler heads with plastic shipping clips still installed and one sprinkler head deflector bent.
BLD-Final11/16/200711/19/200711/19/2007ANR
DetailsMike Jordan
ROBERT Phone #: ###-####. Needs to have insp. fire insp. first. Contractor was contacted and notified.
FIRE-Final Inspection11/15/200711/16/200711/16/2007PCANC
DetailsTroy Cobbley
Scheduled by a contractor via Hello! on 11/15/2007 at 5:03:07 PM. Contact: ###-####. I called the contact number and left a message about the fire sprinkler permit only having a rough-in inspection and no final at this time. Without a fire sprinkler final there can be no fire life safety sign off.
BLD-Other11/8/200711/8/200711/9/2007PCANC
DetailsMike Jordan
john - partial drywall - one side drywall Phone #: ###-####
BLD-Framing/Rough-in11/7/200711/8/200711/8/2007APART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 11/7/2007 at 5:54:20 PM. Contact: ###-####. - partial only . interior steel stud walls at new front desk area. pend. elec. Already one sided when on site.
BLD-Conference9/25/20079/26/20079/26/2007ADONE
DetailsMike Jordan
richard Phone #: ###-####