Permit Information
Permit NumberBLD07-00948
StatusFinaled
Name ESI
Site Address 10751 W OVERLAND RD
Project NameFRED MEYER
Customer Number 
ePlanReviewNo
Description
(FRED MEYER - REMODEL AND ADDITION TO GARDEN CENTER) 7/3/07 - PLAN MODIFICATION FOR ELECTRICAL, LIGHTING COMPLIANCE CERTIFICATE AND ELEC/PLUMBING STAMPED "7/3/07, PLAN MOD. RESUBMITTAL" WERE CHANGED. ALL OTHER PLAN REVIEW CONDITIONS AND PLAN SHEETS REMAIN AS ORIGINALLY APPROVED. This building is fully sprinklered for allowable area increase. Work includes selective demolition to prepare for new interior layout and finishes for existing sales floor display and customer service areas of 169,458 sq. ft. main floor and preparation of Garden Center area for construction of a 3,000 sq. ft. cover with support structure and expansion of the outdoor garden/sales area to become 8,871 sq. ft. To construct a new wall to create a new 1,440 sq. ft. (1,392 interior) merchandise pick-up area; add a new loading platform, stairs and rails in the dock area from existing storage area; add a new overhead door to the garden sales/display area and man door as an exit directly to the exterior along the exterior side of new fenced in garden open sales site from the new MPA. To upgrade interior ceilings, floors and wall finishes; display fixtures, freezers, coolers, display and service counters; upgrade bakery equipment and relocate Type I hood with protected grease duct exhaust system; upgrade electrical, mechanical and plumbing; replace interior and exterior doors as indicated, all per approved plans. DRH07-00150 & CFH07-00015. drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/8/20081/8/20081/8/2008PPASS
DetailsMike Jordan
All issues resolved. Final ok.
BLD-Final12/19/200712/20/200712/20/2007AFAIL
DetailsMike Jordan
Scheduled by a contractor via Hello! on 12/19/2007 at 10:01:03 AM. Contact: ###-####. Needs to provide 36x36 counters for checkout stands, nedds to be dispursed.
FIRE-Final Inspection12/19/200712/19/200712/19/2007PPASS
DetailsTroy Cobbley
Life safety passed.
FIRE-Final Inspection12/4/200712/5/200712/5/2007AFAIL
DetailsTroy Cobbley
The duct smoke detectors have been installed on the supply side not the return side as required per the IMC. The testing has been stopped.
FIRE-Final Inspection11/19/200711/20/200711/20/2007AFAIL
DetailsTroy Cobbley
Still waiting to final the fire alarm permit then the life safety inspection can be started.
FIRE-Final Inspection11/16/200711/19/200711/19/2007AFAIL
DetailsTroy Cobbley
Need the project related fire alarm permit finaled.
FIRE-Final Inspection11/15/200711/16/200711/16/2007AFAIL
DetailsTroy Cobbley
The project is not ready for a final yet but the ham hood is ok to use.
Code Occupancy Approval11/14/200711/14/200711/14/2007APASS
DetailsScott M.Brown
OK FOR FINAL
FIRE-Final Inspection11/12/200711/13/200711/13/2007AFAIL
DetailsTroy Cobbley
The project is not ready for a final inspection yet. The inspection for today was just for the installation and/or repair of the exit discharge lights. They now work.
FIRE-Final Inspection11/6/200711/7/200711/7/2007AFAIL
DetailsTroy Cobbley
The inspection today was to test the new and existing exit signs and emergency lights. Everything operated ok but exit discharge lights are missing from all of the exits. Exit discharge lights do not need to be added outside of the two exits in the Garden Area due to the interior lighting and two parking lot lights that are powered from the emergency generator that provide adequate lighting.
FIRE-Final Inspection10/31/200711/1/200711/2/2007AFAIL
DetailsTroy Cobbley
This was actually for a conference. I provided a correction notice siting specific code sections for life safety requirements. These code sections were written as follows: (1) Provide a racking permit as per IBC section 2208. Contact Dan Stuart at ###-####. (2) Provide Means of Egress Illumination as per IFC 1006.1 This includes the exit discharge. Emergency power shall be per IFC 1006.3. This is to be in the scope of work and in all paths of exit from the scope of work/remodeled areas. (3) Provide exit signs as per IFC 1011.1. Also see IFC 1011.53 for power source. This is to be in the scope of work and in all paths of exit from the scope of work/remodeled areas. (4) Provide door hardware that complies with IFC 1008.1.8.1 and 1008.1.8.3. (5) Access controlled egress doors, such as in Daycare, must comply with IFC 1008.1.3.4 or receive variance from Dan Stuart ###-####.
BLD-Framing/Rough-in10/17/200710/17/200710/17/2007PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 10/17/2007 at 9:04:04 AM. Contact: ###-####. ceiling grid ok.
FIRE-Conference10/17/200710/17/200710/17/2007PDONE
DetailsTroy Cobbley
I deferred a fire watch request to dave hanniman and answered general questions about a racking permit.
BLD-Wall cover10/16/200710/16/200710/16/2007APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 10/16/2007 at 7:27:51 AM. Contact: ###-####. ceiling grid ok, Main restrooms ok.
FIRE-Conference10/6/200710/8/200710/8/2007ADONE
DetailsTroy Cobbley
Conference was for the life safety requirements in the new garden area.
BLD-Conference10/8/200710/8/200710/8/2007PPART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 10/8/2007 at 9:50:45 AM. Contact: ###-####. ceiling grid in seafood area ok. pend. fire.
BLD-Other9/28/20079/28/20079/28/2007APART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 9/28/2007 at 7:28:16 AM. Contact: ###-####. soffit at seafood area, ceiling grid, pend. sprinkler.
BLD-Other9/11/20079/11/20079/11/2007APART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 9/11/2007 at 5:45:46 AM. Contact: ###-####. ceiling grid ok, pending fire.
FIRE-Final Inspection9/6/20079/7/20079/7/2007AFAIL
DetailsTroy Cobbley
This was an inspection for the egress corridor near the bakery. I need verification that this corridor has emergency lighting. I also noticed overspaced pendants in the bakery that need addressed prior to a final.
BLD-Other9/4/20079/4/20079/4/2007PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 9/4/2007 at 9:48:04 AM. Contact: ###-####. Ceiling grid in bakery ok.
BLD-Other8/31/20078/31/20078/31/2007PNR
DetailsDave Hannah
Scheduled by a contractor via Hello! on 8/31/2007 at 7:37:14 AM. Contact: ###-####.
FIRE-Final Inspection8/27/20078/27/20078/27/2007PPART
DetailsTroy Cobbley
The remodeled pharmacy area is ok to occupy.
BLD-Final8/27/20078/27/20078/27/2007PCANC
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/27/2007 at 8:54:03 AM. Contact: ###-####.
BLD-Other8/27/20078/27/20078/27/2007PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/27/2007 at 8:54:03 AM. Contact: ###-####. Pharmacy ok.
BLD-Final8/24/20078/24/20078/24/2007ACANC
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/24/2007 at 6:51:21 AM. Contact: ###-####.
BLD-Other8/24/20078/24/20078/24/2007APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/24/2007 at 6:51:21 AM. Contact: ###-####. Ceiling grid insp. Received RFI # 16 from arcchitect changing grid requirements to 0-2 application.
BLD-Other8/20/20078/20/20078/20/2007PFAIL
DetailsMike Jordan
Ceiling grid not installed as per plan. c/n issued.
FIRE-Final Inspection8/17/20078/17/20078/17/2007PPART
DetailsTroy Cobbley
This inspection was for the electronics area only. This area is ok to occupy.
FIRE-Conference8/15/20078/15/20078/15/2007PDONE
DetailsTroy Cobbley
This inspection was for the electronics area only. I found six missing sprinkler heads. See the city approved fire sprinkler plans for locations.
BLD-Final8/15/20078/15/20078/15/2007PNR
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/15/2007 at 8:00:02 AM. Contact: ###-####. Not a blg. final. Looking to move in to new electronics area. Needs fire to final. Grid system installed not as per plan. Need RFI from architect prior to signing off grid system.
BLD-Conference8/15/20078/15/20078/15/2007PCANC
DetailsMike Jordan
Nate; Phone #: ###-#### Internet Inspection Request from: Hattie James Inspection cancelled from web by: Hattie James
BLD-Other8/13/20078/14/20078/14/2007APART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/13/2007 at 6:04:03 PM. Contact: ###-####. Received and reviewed paperwork for polycoolite that arrived on site. Paperwork from SGS testing labs indicates that this shipment carries a CC1 rating as required. Will have paperwork scanned in with permit. Allso noted that railing and stairs at docks has been added back in. Plans must be submitted to architect for approval then resubmitted to plan review for approval.
BLD-Energy code compliance8/13/20078/13/20078/13/2007APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/13/2007 at 6:46:25 AM. Contact: ###-####. insul at new pickup demissing wall.
BLD-Framing/Rough-in8/8/20078/8/20078/8/2007PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/8/2007 at 9:16:20 AM. Contact: ###-####. New demissing wall for merchandising/pickup room.
FIRE-Alarm Testing8/2/20078/3/20078/3/2007ADONE
DetailsTroy Cobbley
This inspection actually turned into a conference. I spoke to the superintendant and told him that for the two hood suppression systems all I need is the certification from the hood suppression contractor that states they are ok with the new appliances and setup. I also was shown what was going on in the rest or the store as far as sprinkler work. This work is in progress and has a early start go ahead.
BLD-Other8/2/20078/2/20078/2/2007PPART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 8/2/2007 at 10:33:11 AM. Contact: ###-####. Framing for new soffitt at deli area.
BLD-Footing7/31/20077/31/20077/31/2007PPART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 7/31/2007 at 8:56:25 AM. Contact: ###-####. wip for footing for new wall at exisiting garden center. Noted special insp. on site.
BLD-Footing7/27/20077/30/20077/30/2007APASS
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 7/27/2007 at 12:27:28 PM. Contact: ###-####. pendig spec insp
BLD-Framing/Rough-in7/19/20077/19/20077/19/2007APART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 7/19/2007 at 6:29:35 AM. Contact: ###-####. Inspected new soffit framing, and exisiting modified soffitts. Will need RFI from architect for framing changes on diamond soffitt in elec\tronics and for change in grid system. Also reviewed plan review report with contractor.
BLD-Conference6/28/20076/29/20076/29/2007ADONE
DetailsMike Jordan
craig Phone #: ###-####