BLD-Final | 11/6/2009 | 11/6/2009 | 11/6/2009 | P | PASS |
Jim Sly
|
|
|
Chris Mason ###-####//please call 10 min prior to meet you for access. OK for Perm Occ.
|
FIRE-Final Inspection | 10/21/2009 | 10/22/2009 | 10/22/2009 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed. No sign off card was available on site.
|
FIRE-Final Inspection | 8/10/2009 | 8/10/2009 | 8/10/2009 | P | FAIL |
Troy Cobbley
|
|
|
Several items on the correction notice, but not all, have been addressed. The remaining items are, repair the exit sign/emergency, exit discharge light at the east exit of the club house, provide the panic hardware at both of the pool area exits, provide verification of the non compliant fire lane width with mark senteno, provide the missing exit discharge light at the main exit and provide the single action hardware on the office door as discussed.
|
FIRE-Final Inspection | 8/7/2009 | 8/10/2009 | 8/10/2009 | A | FAIL |
Troy Cobbley
|
|
|
Chris Phone #: ###-####. I left a message on Chris's phone and spoke to two people on site but they did not know where Chris was at. No inspection was performed.
|
BLD-Final | 4/22/2009 | 4/23/2009 | 4/23/2009 | A | NR |
Jim Sly
|
|
|
Contacted Chris Mason.....left VM...Need fire and Zoning finals.....cch-jdbj
|
BLD-Final | 4/21/2009 | 4/22/2009 | 4/22/2009 | A | CANC |
Jim Sly
|
|
|
|
BLD-Final | 4/20/2009 | 4/21/2009 | 4/21/2009 | A | CANC |
Jim Sly
|
|
|
Re-sched....
|
BLD-Final | 3/3/2009 | 3/3/2009 | 3/3/2009 | A | FAIL |
Jim Sly
|
|
|
Need Fire and Zoning finals.
|
BLD-Final | 12/18/2008 | 12/19/2008 | 12/19/2008 | A | NR |
Jim Sly
|
|
|
Ted Phone ###-#### Need fire and Zoning.....
|
FIRE-Final Inspection | 10/20/2008 | 10/21/2008 | 10/21/2008 | A | FAIL |
Troy Cobbley
|
|
|
Provide fire dept access roads with the required 20' min width as per the review comments. See IFC 503.2.1. Provide fire extinguishers as per review comment #5. Provide exit signs and emergency lighting per review notes 13, 14 and drawing sheets E1.0 and E2.0L. Provide panic hardware at gates as per drawing sheet A1.1. The maglock at door 100 must meet the requirements of IFC 1008.1.3.4 and be tested. Repair the already installed exit signs and emergency lights. Provide single action hardware, (remove keyed lock) on door 102. Remove locking hardware at door 110A. Provide occupant load signs as per the review comments and drawings. Provide a building address.
|
BLD-Energy code compliance | 5/8/2008 | 5/9/2008 | 5/9/2008 | P | PASS |
Jim Sly
|
|
|
chris Phone #: ###-####
|
BLD-Framing/Rough-in | 5/7/2008 | 5/8/2008 | 5/8/2008 | A | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 5/7/2008 at 4:45:29 PM. Contact: ###-####. Pool Equipment bldg OK to cover.
|
BLD-Final | 3/14/2008 | 3/14/2008 | 3/14/2008 | P | NR |
Jim Sly
|
|
|
Allen ###-####
|
BLD-Energy code compliance | 3/11/2008 | 3/11/2008 | 3/11/2008 | P | PASS |
Jim Sly
|
|
|
allen Phone #: ###-####
|
BLD-Framing/Rough-in | 2/21/2008 | 2/22/2008 | 2/22/2008 | A | PASS |
Jim Sly
|
|
|
alan Phone #: ###-#### Called Alan.....Need to fireblock above fire place.
|
BLD-Foundation | 2/12/2008 | 2/12/2008 | 2/13/2008 | A | PART |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 2/12/2008 at 6:55:28 AM. Contact: ###-####. Footing and wall appears OK....unable to determine setbacks.......Pool equipment room.
|
BLD-Foundation | 1/10/2008 | 1/11/2008 | 1/11/2008 | A | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 1/10/2008 at 3:55:01 PM. Contact: ###-####.
|
BLD-Footing | 1/9/2008 | 1/10/2008 | 1/10/2008 | A | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 1/9/2008 at 3:14:13 PM. Contact: ###-####.
|
BLD-Footing | 1/4/2008 | 1/7/2008 | 1/7/2008 | P | CANC |
Jim Sly
|
|
|
amy Phone #: ###-#### Canc by Contr
|