BLD-Final | 8/21/2008 | 8/21/2008 | 8/21/2008 | A | PASS |
Jim Storey
|
|
|
final ok for occ.
|
BLD-Final | 6/27/2008 | 6/30/2008 | 6/30/2008 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 6/27/2008 at 3:13:30 PM. Contact: ###-####. final ok. card on site.
|
BLD-Final | 6/16/2008 | 6/17/2008 | 6/17/2008 | A | NR |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 6/16/2008 at 4:36:17 PM. Contact: ###-####. need mech final/ fire chalking at 2 hr. fire barrior.
|
Code Occupancy Approval | | | 6/6/2008 | | DONE |
|
|
|
|
FIRE-Final Inspection | 6/3/2008 | 6/4/2008 | 6/4/2008 | A | PASS |
Forrest France
|
|
|
Fire life safety passed, egress issues at the new beer cooler to be addressed under separate permit for work in that area.
|
BLD-Final | 6/3/2008 | 6/4/2008 | 6/4/2008 | P | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 6/3/2008 at 3:39:05 PM. Contact: ###-####. ok for temp occ.
|
BLD-Final | 5/29/2008 | 5/30/2008 | 5/30/2008 | P | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 5/29/2008 at 4:31:37 PM. Contact: ###-####.pending fire.
|
FIRE-Final Inspection | 5/29/2008 | 5/30/2008 | 5/30/2008 | A | PART |
Forrest France
|
|
|
East office area defficiencies corrected, some items at the warehouse area remain to be repaired, also need project related fire sprinkler permit finals.
|
FIRE-Final Inspection | 5/28/2008 | 5/29/2008 | 5/29/2008 | A | FAIL |
Forrest France
|
|
|
Project related fire sprinkler permits are not ready for final, noted new beer cooler does not provide adequate egress under door failure conditions.
|
FIRE-Final Inspection | 5/27/2008 | 5/28/2008 | 5/28/2008 | P | NR |
Forrest France
|
|
|
Scheduled by a contractor via Hello! on 5/27/2008 at 3:54:24 PM. Contact: ###-####.
|
FIRE-Final Inspection | 5/21/2008 | 5/22/2008 | 5/22/2008 | A | FAIL |
Forrest France
|
|
|
Several items noted including exit aisles at the north warehouse area are blocked by product storage, one ESFR head is obstructed by a roof drain, missing fire dept. key box, need to repair two exit signs, missing fire door signage and max occupant signage, need to post building address, missing doors at the new vestibule, three heads at the office area are out of adjustment, missing discharge light at the south office exit, need additional fire extinguishers at the second level warehouse office and lower level riser room, project related fire sprinkler and alarm permits need finaled, no other life safety items reviewed at this time, some phases of construction are still underway, permanent occupancy at the remodeled office area is not permitted at this time per discussion with the contractor.
|
BLD-Final | 5/16/2008 | 5/19/2008 | 5/19/2008 | A | DEFR |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 5/16/2008 at 3:50:09 PM. Contact: ###-####. to pm.
|
BLD-Final | 5/15/2008 | 5/16/2008 | 5/16/2008 | A | FAIL |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 5/15/2008 at 3:13:38 PM. Contact: ###-####. do not occupy office area.
|
BLD-Energy code compliance | 4/30/2008 | 4/30/2008 | 4/30/2008 | P | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 4/30/2008 at 9:00:38 AM. Contact: ###-####.insulation ok
|
BLD-Framing/Rough-in | 4/25/2008 | 4/28/2008 | 4/28/2008 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 4/25/2008 at 4:12:29 PM. Contact: ###-####.
|
BLD-Framing/Rough-in | 4/16/2008 | 4/17/2008 | 4/17/2008 | A | PASS |
Jim Storey
|
|
|
andy - cover Phone #: ###-#### fire collors on plm pipe ok to cover.
|
BLD-Final | 4/10/2008 | 4/11/2008 | 4/11/2008 | P | CANC |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 4/10/2008 at 12:05:36 PM. Contact: ###-####.
|
BLD-Framing/Rough-in | 4/9/2008 | 4/9/2008 | 4/9/2008 | P | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 4/9/2008 at 11:16:30 AM. Contact: ###-####. exterior office framing ok to cover.
|
BLD-Framing/Rough-in | 3/24/2008 | 3/25/2008 | 3/25/2008 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 3/24/2008 at 2:46:53 PM. Contact: ###-####.
|
BLD-Framing/Rough-in | 3/19/2008 | 3/20/2008 | 3/20/2008 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 3/19/2008 at 12:44:41 PM. Contact: ###-####.
|
BLD-Conference | 3/5/2008 | 3/5/2008 | 3/6/2008 | P | PASS |
Jim Storey
|
|
|
dan --call 1st before insp Phone #: ###-#### ok to cover office and first layer ok on 3 hr stud waa.
|
BLD-Framing/Rough-in | 3/5/2008 | 3/6/2008 | 3/6/2008 | A | FAIL |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 3/5/2008 at 5:27:58 PM. Contact: ###-####. c/n on sm office stairs rise and run/fire blocking/ 5' header sizing
|