Permit Information
Permit NumberBLD07-03156
StatusFinaled
Name WELLMAN CONSTRUCTION
Site Address 8125 W FAIRVIEW AVE
Project NameSHOPKO PLAZA
Customer Number 
ePlanReviewNo
Description
(GANDOLFOS NEW YORK DELI - SHOPKO PLAZA) To build-out a 1,500 sq.ft. area of a 5,880 SHELL building to be used as a deli style restaurant per approved plans. Work includes construction of a 2-hour fire barrier wall between this 'A2' occupancy and other areas of building to create own fire area instead of sprinkler system. Interior walls to create a kitchen, two fully accessible restrooms, accessible route to all areas, service & dining area; install a type I hood with protected grease duct exhaust system, a type II hood; new electrical, mechanical and plumbing; suspended ceiling grid system, millwork and finishes. drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/9/20084/9/20084/9/2008PPASS
DetailsMike Jordan
jim Phone #: ###-####. ok for perm occ.
BLD-Final3/14/20083/14/20083/14/2008PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 3/14/2008 at 5:54:04 AM. Contact: ###-####.
OK for Temp.......Waiting for Plumb, Electr, and CDHD to Perm.
FIRE-Final Inspection3/13/20083/14/20083/14/2008APASS
DetailsTroy Cobbley
life safety passed
FIRE-Final Inspection3/12/20083/13/20083/13/2008PFAIL
DetailsTroy Cobbley
Emergency lights and exit signs had not been mounted yet. Door hardware to the restrooms had not been mounted yet. The duct smoke detector needs the remote annunciator mounted and everything tested or the duct detector to be removed since it is not required per IMC.
BLD-Other3/11/20083/12/20083/12/2008APART
DetailsMike Jordan
Jim, ceiling grid; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. pend elec ri above grid, also needs to wire diffusers andv finish installing clips on grid. Also inspected firecaulking at 2hr fire barrier wall for membrane and through penetrations. Will check remainder of grid on final.
BLD-Other2/20/20082/21/20082/21/2008APART
DetailsMike Jordan
james - first sheet on 2 hr fire wall Phone #: ###-####. ok to place 2nd layer.
BLD-Framing/Rough-in2/12/20082/13/20082/13/2008APASS
DetailsMike Jordan
jim Phone #: ###-####. Interior walls and hardlid only.