Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD08-00277
StatusFinaled
Name ALPINE CONSTRUCTION INC
Site Address 2758 S FEATHERLY WAY
Project NameSheffield Building #1
Customer Number 
ePlanReviewNo
Description
(ADA COUNTY EMS - SHEFFIELD BUILDING #1) To build out and finish a 2,432 sq. ft. portion of an 7,800 sq. ft. building as an office, activity area, kitchen, three residential sleeping rooms, office and one emergency vehicle parking garage for Ada County Paramedics per approved plans and CUP07-00143.This BUILDING is to be fully sprinklered as a condition of this permit due to residential occupancy. Work includes construction of interior non-bearing walls to create the office, dining/living, kitchen, mechanical, bedrooms, laundry, restrooms, data and ambulance storage rooms. Plans indicate a 1-hour wall between this tenant space and space to east and between the ambulance storage and other use areas with door/frame/hardware assemblies of 60 minutes for doors 102A & 106. Work also includes new suspended ceiling grid system installed per CISCA guidelines in main areas and hard drywall lid in ambulance storage, restrooms, sleeping , mechanical and data rooms; upgrade electrical, mechanical & plumbing and install new NFPA 13 sprinkler with alarm system throughout the building as a condition of this permit due to 'R' occupancy sleeping rooms. All per approved plans including red-lined notes on plans and all attached plan review comments and conditions of all reviewing agencies for this project. drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/14/20087/16/20087/16/2008APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 7/14/2008 at 12:29:05 PM. Contact: ###-####. - please call 1/2 hr prior to inspection. Ok for perm occ.
BLD-Final7/10/20087/11/20087/11/2008PPART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 7/10/2008 at 12:41:41 PM. Contact: ###-####. Ok for temp occ...Needs to install tactile exit sighns at enterance/exits.
FIRE-Final Inspection7/10/20087/11/20087/11/2008APASS
DetailsTroy Cobbley
fire life safety passed
FIRE-Final Inspection7/9/20087/10/20087/10/2008PFAIL
DetailsForrest France
No approved city plan on site, egress lights at front and back entrances did not function and front door hardware was in correct.KR
BLD-Final7/7/20087/8/20087/8/2008PCANC
DetailsMike Jordan
A.J Phone #: ###-####
BLD-Other7/8/20087/8/20087/8/2008PPASS
DetailsMike Jordan
A.J Phone #: ###-####. Ceiling grid ok.
BLD-Framing/Rough-in5/22/20085/23/20085/23/2008APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 5/22/2008 at 3:49:15 PM. Contact: ###-####.. Interior walls and harlids ok. no grid. Will call back on 1hr wall.
BLD-Framing/Rough-in5/5/20085/6/20085/6/2008ANR
DetailsMike Jordan
Scheduled by a contractor via Hello! on 5/5/2008 at 1:14:06 PM. Contact: ###-####. Stiil needs plumbing and mech ri insp. prior to framing insp.