BLD-Final | 7/10/2008 | 7/11/2008 | 7/11/2008 | A | PASS |
Tom Arcoraci
|
|
|
Jason Phone #: ###-####
|
BLD-Final | 7/3/2008 | 7/3/2008 | 7/3/2008 | P | FAIL |
Mike Jordan
|
|
|
Faith Phone #: ###-####.. only one main enterance allowed to have locking hardware, needs to provide panic hardware on other main door. Lever hardware required on both doors in back office. Also needs to provide ADA compliant sales counter. c/n posted.
|
FIRE-Final Inspection | 7/2/2008 | 7/3/2008 | 7/3/2008 | P | PASS |
Forrest France
|
|
|
All corrections made per last inspection. KR
|
FIRE-Final Inspection | 7/1/2008 | 7/2/2008 | 7/2/2008 | A | FAIL |
Forrest France
|
|
|
Exit light in rear storage room did not function, Egress lights were not installed and are required based on occupancy load. KR
|
BLD-Final | 7/1/2008 | 7/2/2008 | 7/1/2008 | P | NR |
Tom Arcoraci
|
|
|
Jason Phone #: ###-####
|
BLD-Framing/Rough-in | 6/19/2008 | 6/20/2008 | 6/20/2008 | A | PART |
Tony Young
|
|
|
jason - ceiling grid Phone #: ###-#### grid ok pending others,
|
BLD-Wall cover | 6/2/2008 | 6/3/2008 | 6/3/2008 | A | PEND |
Tom Arcoraci
|
|
|
|
BLD-Framing/Rough-in | 5/30/2008 | 6/2/2008 | 6/2/2008 | A | PASS |
Tom Arcoraci
|
|
|
Jason; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
|
BLD-Framing/Rough-in | 5/12/2008 | 5/12/2008 | 5/12/2008 | P | PASS |
Tom Arcoraci
|
|
|
Derek ###-#### main walls and bath ok
|
BLD-Framing/Rough-in | 5/8/2008 | 5/8/2008 | 5/8/2008 | P | NR |
Tom Arcoraci
|
|
|
derick - please call 1/2 hr prior to inspection Phone #: ###-####
|