Permit Information
Permit NumberBLD09-00887
StatusFinaled
Name CM COMPANY
Site Address 1507 N 28TH ST
Project NameLOWELL ELEMENTARY SCHOOL
Customer Number 
ePlanReviewNo
Description
(LOWELL ELEMENTARY) Remodel of an existing 41,741 sq. ft. school building, exterior site accessibility, additional parking and structural upgrade & connections as per engineering & per approved plans. Work includes select structural & interior finish demolition for the express purpose of removing asbestos, lead containing materials and finishes and to upgrade accessibility between floors within the building and from the exterior school site to the interior of the building and the public way to the school grounds; and to install a sprinkler / alarm systems throughout. Scope of work includes removal of doors, hardware & finishes; remodel administrative offices, workroom & lounge; install new doors and hardware; construct new elevator, ADA ramps, upgrade security, lighting, HVAC & plumbing; construct new interior walls, millwork and finishes; and all associated site work all as indicated in the reviewed plans. Permit BLD09-00888 is also attached to the same set of plans for a 692 sq. ft. garage/maintenance building. drs CUP09-00019 - Modification
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/12/20108/12/20108/12/2010PPASS
DetailsTony Young
Jim Phone #: ###-####
BLD-Final8/11/20108/12/20108/12/2010APASS
DetailsTony Young
Jim Phone #: ###-####
BLD-Final7/30/20108/2/20108/10/2010APART
DetailsTony Young
Jim Phone #: ###-####,, need final architect reports... etc. need exterior stair issues resolved
BLD-Final7/29/20107/30/20107/30/2010PPART
DetailsTony Young
Jim Phone #: ###-####,, temp ok pending others
FIRE-Final Inspection7/23/20107/26/20107/26/2010PPASS
DetailsForrest France
Corrections field verified for completion. Fire life safety passed.
FIRE-Final Inspection7/22/20107/23/20107/23/2010AFAIL
DetailsForrest France
Missing one EM light at the counselors room 1st floor per plan, install one exit sign with directional arrow per plan at the 1st floor north corridor, add one EM light at the basement level band room, provide one missing PFE at the 2nd floor, post max occupant signs at the cafeteria and gym as discussed. Remainder of fire life safety items okayed.
FIRE-Conference7/20/20107/20/20107/20/2010ADONE
DetailsForrest France
Discussion with contractor regarding project completion and trade permit work.
BLD-Other6/7/20106/8/20106/8/2010PPASS
DetailsTony Young
jim - overhead ceiling tile cover Phone #: ###-####,, basment ok
BLD-Conference5/27/20105/28/20105/28/2010APART
DetailsTony Young
Jim Stubbs Phone #: ###-####
stair ?s,, ceilings ok pending others
BLD-Other5/24/20105/25/20105/26/2010PPASS
DetailsTony Young
ceiling cover Phone #: ###-####,, main halls ok
BLD-Framing/Rough-in5/24/20105/24/20105/24/2010PPART
DetailsTony Young
ceiling cover Phone #: ###-####,, main hallway needs more firecaulking,, tie all wires,, conf on basement ceiling
BLD-Framing/Rough-in4/26/20104/26/20104/27/2010PCANC
DetailsTony Young
rob Phone #: ###-####
BLD-Framing/Rough-in4/27/20104/27/20104/27/2010APART
DetailsTony Young
rob Phone #: ###-####,, grid work in progress,, also conf on north/ east landing and stair,, need to rebuild to meet code
BLD-Other4/26/20104/27/20104/27/2010APART
DetailsTony Young
rob Phone #: ###-####,, ceiling grid,, north of main level grid ok,, upper level ok
FIRE-Conference2/24/20102/24/20102/26/2010PDONE
DetailsForrest France
On site meeting with project architect regarding IFC sec. 906 and IDAPA amendments.
FIRE-Final Inspection2/24/20102/24/20102/24/2010PCANC
DetailsForrest France
Incorrect inspection type, not intended for final.
BLD-Framing/Rough-in2/16/20102/17/20102/17/2010PPART
DetailsTony Young
Ceiling cover inspection please-Rob Phone #: ###-####
north stairs ok x 2
BLD-Other1/29/20101/29/20101/29/2010PPART
DetailsTony Young
Rob this is foe the fire lid in elevator shaft Phone #: ###-####elevator room and elevator lid 1st layers ok
BLD-Framing/Rough-in1/20/20101/20/20101/20/2010PPART
DetailsTony Young
Rob Phone #: ###-####
main level main lav ceiling ok
FIRE-Conference1/15/20101/15/20101/15/2010ADONE
DetailsForrest France
Conference with general contractor regarding NFPA 13 2007 sec. 8.15.1.2.-8.15.2.2.
BLD-Framing/Rough-in1/14/20101/14/20101/14/2010PPART
DetailsJim Sly
rob Phone #: ###-####
OK to cover chase walls located between main restrooms....1st floor....and lids at 3 small restrooms at South end bldg (Kindergarten area).
BLD-Framing/Rough-in1/7/20101/7/20101/7/2010PPART
DetailsTom Arcoraci
Rob Phone #: ###-#### two hard lids south side,studs in hall for new support, non bearing walls 2 west side 1 east ok
BLD-Framing/Rough-in12/23/200912/23/200912/24/2009PPART
DetailsTony Young
Rob Phone #: ###-####
hard lids in rest rooms
BLD-Framing/Rough-in12/11/200912/14/200912/14/2009APART
DetailsTony Young
Rob Phone #: ###-####
interior walls as noted on plans
BLD-Framing/Rough-in12/3/200912/4/200912/4/2009APART
DetailsTony Young
Rob Phone #: ###-####
upper floor hall way bearing walls,, pending trades ok to insulate and cover
BLD-Framing/Rough-in12/3/200912/3/200912/3/2009PDEFR
DetailsTony Young
Rob Phone #: ###-####
out of time, told him he could insulate,, re scheduled for 12/4
BLD-Framing/Rough-in11/12/200911/16/200911/16/2009APART
DetailsTony Young
rob Phone #: ###-####
some interior walls,, ok pending trades r/in,,, siesmic ties in roof on So. end,, other ties ok pend engineer letter of ok
BLD-Framing/Rough-in10/27/200910/28/200910/28/2009APART
DetailsTony Young
Rob Phone #: ###-####
2nd floor floor ties ok on north wing pending special inspection report,, also 2 ties at entry
BLD-Framing/Rough-in10/26/200910/27/200910/27/2009ANR
DetailsTony Young
Rob Phone #: ###-####
BLD-Framing/Rough-in9/18/20099/21/20099/21/2009APART
DetailsTom Arcoraci
Rob Phone #: ###-#### wip ok
BLD-Framing/Rough-in9/17/20099/17/20099/17/2009PPART
DetailsJim Storey
rob Phone #: ###-#### roof straping and nailling ok marked plan as to location.
BLD-Framing/Rough-in9/4/20099/8/20099/8/2009PPART
DetailsTony Young
rob Phone #: ###-####
seismic ties roof area 1 and 5
FIRE-Conference2/16/20102/16/2010 P 
DetailsForrest France
Don H. Phone #: ###-####