Permit Information
Permit NumberBLD09-00962
StatusFinaled
Name CUSTOM STEEL STRUCTURES
Site Address 7908 W WOODLARK ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Bolens Control House - Electrical Warehouse - To construct a new 4,232 square foot, one story, storage warehouse building, and related site improvements. This building is constructed of pressure treated 6X6 columns, corrugated steel wall panels, 2X6 horizontal wall girts flat to columns at 16" o.c., double wood girder trusses at 10' o.c., and prefinished corrugated metal roofing. This building is not fire sprinkled. All construction shall be per the approved plans, Engineering, and attached comment list. The construction for the mezzanine and future restroom require separate permits. Racking is not part of this permit. Separate permits are required for storage racking. A new Certificate of Occupancy with the occupant load total is to be issued when completed and approved prior to tenant occupying this building.**SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/17/20112/22/20112/22/2011APASS
DetailsMike Jordan
curt - please call 1/2 hr prior so he can meet you there Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection2/16/20112/17/20112/17/2011APASS
DetailsTroy Cobbley
life safety passed
FIRE-Conference11/12/201011/15/201011/15/2010ADONE
DetailsTroy Cobbley
I left address and permit information on both Mark Sentenno's and Scott Arellano's voice mails.
FIRE-Conference11/12/201011/12/201011/12/2010PDONE
DetailsTroy Cobbley
Kurt; phone ###-####. Kurt and I spoke about the missing fire hydrant. I deferred him to Scott Arellano. I also afterward spoke to Mark Senteno. A conference has been set up for monday to bring scott and mark up to speed on project status.
FIRE-Conference11/10/201011/10/201011/10/2010PDONE
DetailsTroy Cobbley
I met with Tom Bolens and discussed the missing fire hydrant shown on resubmittal sheet A1.0. I deferred him to Scott Arellano for requirement information.
FIRE-Final Inspection11/9/201011/9/201011/9/2010PFAIL
DetailsTroy Cobbley
Provide two Fire Lane - No Parking signs and post them as discussed and provide verification with plan review about possible resubmittals due to the mezzanine not being built.
BLD-Other9/22/20109/22/20109/22/2010PPASS
DetailsMike Jordan
shear inspection//Curt Phone #: ###-####. interior shear walls ok.
BLD-Framing/Rough-in6/14/20106/15/20106/15/2010APART
DetailsMike Jordan
Curt please call 30 min before going out Phone #: ###-####. Ok to install osb roof deck and exterior metal siding. Verified holdowns and all straps.
BLD-Footing4/19/20104/20/20104/20/2010APASS
DetailsMike Jordan
john - rebar Phone #: ###-####. Welded wire mesh and #4 rebar @ 4ft. on center for interior slab on grade ok. Constructed as per approved plans.
BLD-Footing4/6/20104/7/20104/7/2010APASS
DetailsMike Jordan
John Phone #: ###-####.. Reviewed special inspection report on epox dowels for misplaced vertical reinforcement at piers. Also reviewed clarification and reinspected reinforcement for piers. ok for concrete.
BLD-Foundation4/6/20104/6/20104/6/2010PPART
DetailsMike Jordan
ben Phone #: ###-####. Noted that contractor incorrectly placed verts in several loactions at piers. This will require an rfi from engineer of record for repair and special inspection if required. Contractor to also get clarification on pier detail regarding the #3 rebar at 6 inches on center.
BLD-Footing4/1/20104/1/20104/1/2010PPASS
DetailsJim Storey
jay - late afternoon please Phone #: ###-####
BLD-Footing3/26/20103/29/20103/29/2010ANR
DetailsMike Jordan
curt - late morning please Phone #: ###-####. Spoke with curt this morning, he noted some set back issues with bldg. Noted that bldg. is going to have to be moved 3ft. closer to exisiting bldg. to meet the rear setback. Noted to curt to contact plan review and zoning. Plans may have to be resubmitted to city for approval.