BLD-Final | 11/24/2009 | 11/24/2009 | 11/24/2009 | P | PASS |
Mike Jordan
|
|
|
Jarod Phone #: ###-####. Fixtures ok. ok for perm occ.
|
BLD-Final | 11/16/2009 | 11/16/2009 | 11/16/2009 | P | PART |
Mike Jordan
|
|
|
Jared Phone #: ###-####. Ok for temp occ. Still need to check fixtures for ada compliance.
|
BLD-Final | 11/12/2009 | 11/13/2009 | 11/16/2009 | P | NR |
Mike Jordan
|
|
|
Jarod Phone #: ###-####
|
FIRE-Final Inspection | 11/12/2009 | 11/12/2009 | 11/12/2009 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed.
|
BLD-Framing/Rough-in | 10/30/2009 | 11/2/2009 | 11/2/2009 | A | PASS |
Tom Arcoraci
|
|
|
jared - ceiling grid Phone #: ###-####
|
BLD-Framing/Rough-in | 10/29/2009 | 10/30/2009 | 10/30/2009 | A | PART |
Mike Jordan
|
|
|
jared - ceiling grid Phone #: 412-288. Needs to install wires for diffusers.
|
BLD-Other | 10/26/2009 | 10/27/2009 | 10/27/2009 | A | NR |
Mike Jordan
|
|
|
ceiling grid insp//Jared Phone #: ###-####. Needs elec. ri insp. first.
|
BLD-Framing/Rough-in | 10/8/2009 | 10/9/2009 | 10/9/2009 | A | PART |
Mike Jordan
|
|
|
Jared-dry wall inspection please Phone #: ###-####. 5/8 type x rock for vertical exit enclosure.
|
FIRE-Conference | 10/7/2009 | 10/8/2009 | 10/8/2009 | A | DONE |
Troy Cobbley
|
|
|
Went over life safety requirements with contractor. Requiring emergency lights and exit signs in mezzanine.
|
BLD-Energy code compliance | 10/8/2009 | 10/8/2009 | 10/8/2009 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Framing/Rough-in | 10/6/2009 | 10/6/2009 | 10/6/2009 | P | PASS |
Mike Jordan
|
|
|
Jared Phone #: ###-####. Interior framed walls under mezz, mezz framing and roof framing ok.
|
BLD-Framing/Rough-in | 9/29/2009 | 9/29/2009 | 9/29/2009 | P | PART |
Mike Jordan
|
|
|
jared Phone #: ###-####. ok to insulate ceiling. Verified all straps and blocking for roof.
|
BLD-Framing/Rough-in | 9/23/2009 | 9/24/2009 | 9/24/2009 | A | PART |
Mike Jordan
|
|
|
jared Phone #: ###-####. 4" nailing on blocking for roof diaphragm completed. Also visually inspected nailing on interior shearwall ok.
|
BLD-Framing/Rough-in | 9/21/2009 | 9/22/2009 | 9/22/2009 | P | PART |
Mike Jordan
|
|
|
Jared Phone #: ###-####. Nailing for roof diaphragm only. Still needs to nail at 4"oc at blocking.
|
BLD-Concrete | 9/11/2009 | 9/14/2009 | 9/15/2009 | P | DONE |
Mike Jordan
|
|
|
masonary wall insp. Phone #: ###-####
|
BLD-Other | 9/10/2009 | 9/11/2009 | 9/11/2009 | P | PART |
Mike Jordan
|
|
|
Jared-Masonry inspection please Phone #: ###-####
|
BLD-Other | 9/9/2009 | 9/10/2009 | 9/10/2009 | A | PART |
Mike Jordan
|
|
|
jared - masonary wall Phone #: ###-####. wip on masonry wall construction, southwall tow, 17ft. 4in. elev. on remaining walls. special inspector was on site. Also reviewed all special insp. reports to date. No deficiencies were noted.
|
BLD-Other | 9/4/2009 | 9/8/2009 | 9/8/2009 | P | DONE |
Mike Jordan
|
|
|
Jared- wall Phone #: ###-####. Masonry grout placement already completed when on site. Did have special insp.
|
BLD-Concrete | 9/2/2009 | 9/3/2009 | 9/3/2009 | P | PART |
Mike Jordan
|
|
|
Jared Phone #: ###-####. Masonry walls from 4ft. to 8ft. elev. work in progress. Perimeter walls. oft. to 4ft. ele. for interio masonry walls.
|
BLD-Other | 8/31/2009 | 9/1/2009 | 9/1/2009 | P | PART |
Mike Jordan
|
|
|
Masonary wall inspection please-Jared Phone #: ###-####. Perimeter wall, 0 to4ft. elev. wip. Will have special inspection.
|
BLD-Concrete | 8/27/2009 | 8/27/2009 | 8/27/2009 | P | PASS |
Mike Jordan
|
|
|
slab inspection ready this morning if possible. Phone #: ###-####. Interior footings.
|
BLD-Footing | 8/21/2009 | 8/24/2009 | 8/24/2009 | A | PART |
Mike Jordan
|
|
|
Jared Phone #: ###-####. wip on interior column pad footings. Will have special insp.
|
BLD-Foundation | 8/14/2009 | 8/17/2009 | 8/17/2009 | P | PASS |
Mike Jordan
|
|
|
jared Phone #: ###-####
|
BLD-Footing | 8/11/2009 | 8/12/2009 | 8/12/2009 | P | PART |
Mike Jordan
|
|
|
jared Phone #: ###-####. Perimeter footings. Noted special inspection.
|
BLD-Conference | 8/4/2009 | 8/5/2009 | 8/5/2009 | P | DONE |
Mike Jordan
|
|
|
Jarod Phone #: ###-####. Went over special inspection requirements with contractor as per special inspection start up sheet on approved plans.
|