Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberBLD09-02173
StatusFinaled
Name CM COMPANY
Site Address 805 W FRANKLIN ST
Project NameFranklin Plaza
Customer Number 
ePlanReviewNo
Description
(NEW ENTRY STAIR & UPGRADE OF TWO EXISTING STAIR ENCLOSURES) (FRANKLIN PLAZA) This building is fully sprinklered as substitution for 1-hour construction. Upgrade Agreement on this building attached to this case. Upgrade involves modifying the interior stairs enclousre to serve only three levels to allow existing 1-hour construction. The support columns for the 1-hour enclosure are required to be individually wrapped for 1-hour fire resistance at the first and second floors. columns at third and fourth floors can be encapsulated within the 1-hour wall construction. The beams between supporting columns cary the live and dead load of one floor so they can be encapsulated in the 1-hour enclosure wall. The interior stair will serve as exit from the 4th, 3rd & 2nd floors with a new main entry & exit from the 2nd floor to grade. The existing structure supporting the second floor has an existing 1-hour fire-proof spray throughout. The interior stair will be walled off at the first level, no longer an exit and a 60" high fixed guard rail will be installed at the top of the stairs to prevent use of the stairs to the first floor. A sign will be posted on the new guardrail indicating the enclosure no longer serves the first floor. The door to the enclosure on the 2nd floor will be reversed to swing out of the enclosure in direction of egress. The exterior stair will have the existing framed portion toward the interior of the building upgraded to comply as a 2-hour rated assembly. A steel joist that penetrates the new 2-hour framed wall will also be framed in and covered with (2) layers of 5/8" type X for the full length of the joist as indicated on plans. Doors into the 2-hour enclosure will be upgrades with 90-minute door, frame & hardware assemblies at all four floors. Floor levels will be identified per Sec. 1020.1.6 IBC, within enclosure. Installation of new exterior doors, sidelights, hardware, landing, stairs, guard and handrails from 2nd floor to grade and installation of a non-combustible frame awning, supported from the building at new entry / egress. SPECIAL INSPECTION is required for installation of HILTI Kwik Bolt TZ anchors in accordance with ESR-1917 ATTACHED TO FRONT OF PLANS WITH ENGINEERING DESIGN DATA. drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  2/16/2011  
DetailsTony Young
BLD-Final2/14/20112/14/20112/15/2011PPASS
DetailsTony Young
Tony//scheduled by Ron Hill Phone #: ###-####
BLD-Aging Inspection2/14/20112/14/20112/14/2011 PASS
DetailsTony Young
BLD-Aging Inspection12/15/201012/15/201012/15/2010 PEND
DetailsTony Young
FIRE-Conference10/14/201010/15/201010/15/2010ADONE
DetailsForrest France
Check status of permit, and future agreement-contact Tony @ ###-####
BLD-Conference10/14/201010/15/201010/15/2010APART
DetailsTony Young
Check status of permit, and future agreement//
work in progress on fire alarm
BLD-Aging Inspection8/24/20108/24/20108/27/2010 PEND
DetailsTony Young
BLD-Final6/22/20106/23/20106/23/2010APASS
DetailsTony Young
dan Phone #: ###-####
FIRE-Final Inspection6/22/20106/22/20106/22/2010PNR
DetailsForrest France
Project related fire alarm permit must be finaled prior to life safety final.
BLD-Aging Inspection6/22/20106/22/20106/22/2010 PASS
DetailsTony Young
FIRE-Conference4/22/20104/22/20104/22/2010PDONE
DetailsForrest France
Regarding new exiting at the 2nd floor to grade north side of the building.
BLD-Conference4/13/20104/13/20104/13/2010PPASS
DetailsTony Young
dan Phone #: ###-####,, ?s for final
BLD-Conference4/12/20104/13/20104/13/2010APASS
DetailsTony Young
dan Phone #: ###-####,, general ?s on final issues,, will need fire caulking,, smoke seals, hand rails, signage, etc.. for final
BLD-Footing2/19/20102/19/20102/19/2010PPART
DetailsTony Young
dan Phone #: ###-####
stair landing,, wip