Permit Number | BLD10-00120 |
Status | Finaled |
Name |
INDUSTRIAL STORAGE SYSTEMS
|
Site Address |
5383 W KENDALL ST
|
Project Name | State of Idaho Records |
Customer Number | |
ePlanReview | No |
Description |
(State of Idaho Records - Storage Shelving) Installation of steel storage shelving in accordance with Engineered Design Calcs and Layout plans. Includes 75 steel shelving units, 30" x 69" x 10 feet high with approximately 36" between rows of shelving. The shelving is anchored to the floor with a minimum of one, 3/8" Hilti Kwik Bolt TZ (ESR 1917 - copy attached to plans) per base plate with a minimum of 2" embedment. SPECIAL INSPECTION REQUIRED PER ESR 1917. The shelves are also braced together at top, across the aisles. Installation of 16, 15" x 69" x 10' high steel shelving against the south interior tenant wall. See red-lined layout plan. A Plaque, a minimum of 50 sq. inches, shall be posted in one or more conspicuous places per Section 1.4.2, 2002 RMI Specification & note Sheet SCE1 of 1, 500 pounds maximum per Shelf for 30" deep units and 250 pounds per shelf for 15" deep units. NOTE: Separate applications, plans and permits are required BEFORE any modifications of sprinkler or alarm system can begin. drs
|