Permit Information
Permit NumberBLD10-02929
StatusFinaled
Name SHY-BEE DESIGN
Site Address 3623 E WARM SPRINGS AVE
Project NameHARRIS RANCH POSTAL PAVILION
Customer Number 
ePlanReviewNo
Description
(HARRIS RANCH POSTAL PAVILION 1A) **5-31-11 PLAN MODIFICATION TO INCLUDE: ADD AN ADDITIONAL COVERED PORCH; REMOVE ONE SET OF EXTERIOR DOORS TO ALLOW MORE ROOM FOR MAILBOXES; AND MODIFY THE LANDSCAPE DESIGN. SRZ*** To construct a new 198 square foot, One story, wood framed, post office building intended to house post office boxes for private residences. This structure will have one room that will include a 34" table located in the center, mailbox insert stations, a 34" tall counter, and a service sink. Work to include: Construct the building per plans; install a service sink; HVAC/mechanical work, electrical work, and plumbing work per plans; and interior finish work in compliance with chapter 8 of the 2006 IBC. This building is NOT fire sprinklered. All work per the approved plans, attached plan review comments, and conditions of all reviewing agencies for this project. **SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  3/20/2013  
DetailsBarbara Stitt
Doc finaled per Bob Archibald Ref:BLD10-02928
BLD-Aging Inspection3/13/20133/13/20133/13/2013 PASS
DetailsDave Hannah
FIRE-Final Inspection11/22/201111/22/201111/22/2011APASS
DetailsTroy Cobbley
Life safety passed
BLD-Final11/14/201111/15/201111/15/2011APASS
DetailsDave Hannah
Late morning---Tim Phone #: ###-####
FIRE-Final Inspection11/14/201111/15/201111/15/2011APASS
DetailsForrest France
Correction items verified for completion. Signature card not available at the time of inspection. Life safety finaled.
FIRE-Final Inspection11/10/201111/14/201111/14/2011AFAIL
DetailsTroy Cobbley
Provide a building address. 4" minimum height of a contrasting color facing the street. Also provide one 2A, 10BC fire extinguisher mounted in a normal path of travel between 5' and 4" above the finish floor with a current inspection tag from a local licenced company. See approved drawing sheet A0.1.
BLD-Final11/10/201111/10/201111/10/2011PNR
DetailsJim Storey
tim Phone #: ###-####
BLD-Framing/Rough-in9/29/20119/30/20119/30/2011APART
DetailsDave Hannah
Tim Phone #: ###-#### ext ok int ok but needs elec rough in
BLD-Footing9/15/20119/15/20119/15/2011PFAIL
DetailsJim Storey
min 24 depth from finsh grade not achived/ front center pad not min 18" dia.
BLD-Footing9/14/20119/15/20119/15/2011ANR
DetailsJim Storey
Tim Phone #: ###-####
BLD-Foundation9/1/20119/2/20119/2/2011APASS
DetailsDave Hannah
dane Phone #: ###-####
BLD-Footing9/1/20119/1/20119/2/2011PPASS
DetailsDave Hannah
Dane Phone #: ###-####