Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD11-00348
StatusFinaled
Name STETSON HOMES INC
Site Address 11433 W GREYLING CT
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 3,650 sq. ft., two story (first story 2,326 sq. ft., second story 1,324 sq. ft.) single family dwelling with 4 bedrooms, 2 1/2 bathrooms, approximately 573 sq. ft. of covered patio/porch and a 851 sq. ft. attached garage per the approved plans, plan review report and any notations. R-1A zoning and setbacks per planning. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/28/20117/28/20117/28/2011PPASS
DetailsMike Jordan
Rusten Phone #: ###-####
DOC - Permit Finaled7/28/20117/28/20117/28/2011PPASS
DetailsMike Jordan
Residential certificate of occupancy was issued.
BLD-Energy code compliance5/24/20115/24/20115/24/2011PPASS
DetailsMike Jordan
BLD-Energy code compliance5/23/20115/24/20115/24/2011AFAIL
DetailsMike Jordan
Still needs to encapsulate insulation at vaulted ceiling area.
BLD-Energy code compliance5/23/20115/23/20115/23/2011ACANC
DetailsMike Jordan
BLD-Energy code compliance5/23/20115/23/20115/23/2011PFAIL
DetailsMike Jordan
rustin Phone #: ###-####. Needs to encapsulate insulation at vaulted ceiling and at truss.
BLD-Framing/Rough-in5/23/20115/23/20115/23/2011PPASS
DetailsMike Jordan
rustin Phone #: ###-####
BLD-Framing/Rough-in5/20/20115/20/20115/20/2011PCANC
DetailsJim Storey
Rustin Phone #: ###-#### R703.6.3 Water-resistive barriers.
Water-resistive barriers shall be installed as required in Section R703.2 and, where applied over wood-based sheathing, shall include a water-resistive vapor-permeable barrier with a performance at least equivalent to two layers of Grade D paper. framer to verify if as framed at tall wall can be justified or if 8" oc stud spaciing per engineering to be corected.// load transpher of beams to ft north side of great rm west end.//nail top chord and webs of second floor girder truss t36/ fur out wing wall at furnce to 2x6 for r-19 insulation.
BLD-Foundation4/7/20114/7/20114/7/2011PPASS
DetailsMike Jordan
jay Phone #: ###-####
BLD-Footing4/6/20114/6/20114/6/2011PPASS
DetailsMike Jordan
jay Phone #: ###-####