Permit Information
Permit NumberBLD11-00961
StatusFinaled
Name STATELL LTD CO
Site Address 609 W MAIN ST
Project NameMAIN STREET BISTRO
Customer Number 
ePlanReviewNo
Description
(MAIN STREET BISTRO - OPERABLE WINDOW WALL SYSTEM) (5-1-12 PLAN MODIFICATION TO CLARIFY PATIO WORK. THIS TENANT HAS A REQUIRED EXIT THAT PASSES THROUGH THE PATIO. GATES ARE NOT ALLOWED IN THE EGRESS PATH FROM THE PATIO UNLESS THE GATE SWINGS IN THE DIRECTION OF EGRESS TRAVEL, DOES NOT SWING OVER THE PUBLIC SIDEWALK, AND HAS PANIC HARDWARE OR NO LATCHING OR LOCKING HARDWARE. A PADLOCK IS NEVER ALLOWED. THE EGRESS PATH THROUGH THE PATIO, AT LEAST 44 INCHES WIDE, MUST BE MAINTAINED CLEAR AND UNOBSTRUCTED.) (4-24-12 PLAN MODIFICATION TO REMOVE THE EXISTING EXTERIOR BAR, THE EXTERIOR LOW HEIGHT MASONRY WALL, AND THE ENTIRE EXTERIOR PATIO SLAB. TO PLACE A NEW EXTERIOR CONCRETE PATIO SLAB ON GRADE, TO CONSTRUCT NEW EXTERIOR 4 FOOT TALL STEEL FRAME WALLS WITH TRANSLUCENT PANELS, AND CONSTRUCT A NEW EXTERIOR BAR. FUTURE GAS FIRE PITS MUST BE LISTED APPLIANCES ALLOWED FOR COMMERCIAL OCCUPANCIES. THEY ARE REQUIRED TO COMPLY WITH THE FIRE CODE. SINCE THE GAS FIRE PITS ARE DECORATIVE APPLIANCES AND ARE NOT PRIMARILY INTENDED TO PROVIDE OUTSIDE HEATING FOR OCCUPANT COMFORT, THEY ARE BEYOND THE SCOPE OF THE ENERGY CODE. WHETHER GLASS OR PLASTIC, THE TRANSLUCENT PANELS MUST COMPLY AS SAFETY GLAZING.) This building is fire sprinklered for area, story, and height increase and for fire area. To remove an existing exterior wall and replace it with a new operable window wall system. The Certificate of Occupancy for the existing tenant will not change. A new concrete landing will be provided for the full length of the window wall system. The operable window wall system with have folding panels with two integral exit doors each having panic hardware. Floor and head tracks will be provided. Structural work includes a steel beam and column moment frame to support gravity and lateral loads. The design of the column footings is a deferred submittal item. Special Inspection is required for epoxy anchors and for welding. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to be maintained in compliance with NFPA 13 as regulated by the Fire Department. **CJW** (DRH11-00060)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/12/20155/13/20155/13/2015PPASS
DetailsDave Hannah
Ted-see spec report in cubby''s Phone #: ###-####
BLD-Final5/5/20155/6/20155/7/2015PPEND
DetailsDave Hannah
Paul Phone #: ###-####
FIRE-Final Inspection5/5/20155/6/20155/6/2015APASS
DetailsKatie Marron
Fire life safety pass. Aging permit; inspection completed in line with BLD 15-00889 inspection.
BLD-Final5/5/20155/5/20155/6/2015PPEND
DetailsDave Hannah
BLD-Aging Inspection3/27/20153/27/20154/3/2015 PEND
DetailsDave Hannah
BLD-Aging Inspection12/5/201412/5/201412/9/2014 PEND
DetailsDave Hannah
BLD-Aging Inspection8/27/20148/27/20149/2/2014 PEND
DetailsDave Hannah
BLD-Other1/8/20141/8/20141/8/2014APART
DetailsDave Hannah
Verified Glazing, panic hardware, exit sign and threshold elevation on exterior doors at patio area all were in compliance. Will have a zoning enforcement visit to require zoning approval for plan modification in patio area.
BLD-Final5/4/20125/4/20125/4/2012PNR
DetailsDave Hannah
LLoyd Phone #: ###-####--around 4 if possible please
FIRE-Final Inspection5/4/20125/4/20125/4/2012PNR
DetailsForrest France
BLD-Framing/Rough-in4/12/20124/12/20124/13/2012PPASS
DetailsDave Hannah
LLOYD Phone #: ###-#### steel coulmns and beam ok to cover