Permit Information
Permit NumberBLD11-01251
StatusFinaled
Name INTEGRATED BUILDERS GROUP
Site Address 7450 W THUNDERBOLT DR
Project NameCapital Educators Credit Union
Customer Number 
ePlanReviewNo
Description
(CAPITAL EDUCATORS FEDERAL CREDIT UNION) *** 1/5/2012 PLAN MODIFICATION TO INCLUDE: REMOVE EXIT SIGNS/LIGHTING FROM HALLWAY 122 & LOAN WORK AREA 117 PER RED-LINES ON SHEET E2.0L. SRZ*** Remodel of an existing 11,321 sq. ft. credit union building per approved plans. Work to include demolition work per plans; moving the existing retail branch from the West building pod to the East building pod; moving the administrative offices from the East building pod to the West building pod; renovation of the retail branch East building pod will include: new offices, teller line, work areas, banking equipment, mechanical and electrical systems, new clerestory ceiling area and entrance; renovation of the West building pod will include: minor modifications to the existing layout, interior finishes, mechanical and electrical upgrades. Whole building work to include: new exterior stucco finishes; new TPO roofing system; modifications to the existing drive system; new metal fabricated entrance canopy; install a new dual height (hi-lo) accessible drinking fountain; related interior finishes in compliance with chapter 8 of the 2009 IBC; new suspended ceiling grid system installed per CISCA guidelines; and exterior site improvements. All work per the approved plans, attached plan review report, and all other reviewing agencies approvals. Interior Demo permit was done under BLD11-00611. An early start/partial permit was done under BLD11-01252. A new Certificate of Occupancy with the new occupant load total is required to be obtained after all work has been inspected and approved and prior to tenant occupying this space. NOTE: This building is NOT fire sprinklered. DRH11-00056, CUP11-00021 **SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/27/20122/28/20122/28/2012APASS
DetailsMike Jordan
Rob Phone #: ###-####. ok for perm occ.
BLD-Final2/24/20122/27/20122/27/2012ANR
DetailsMike Jordan
Rob Phone #: ###-####. Everything ok, needs zoning to sign off first.
FIRE-Final Inspection2/23/20122/23/20122/23/2012PPASS
DetailsTroy Cobbley
life safety passed
FIRE-Final Inspection2/22/20122/23/20122/23/2012AFAIL
DetailsTroy Cobbley
Provide the missing door hardware and the missing exit sign. Rescheduled for this afternoon.
BLD-Energy code compliance1/12/20121/12/20121/12/2012PPASS
DetailsMike Jordan
rob Phone #: ###-####
BLD-Other1/3/20121/4/20121/4/2012APASS
DetailsMike Jordan
Rob Phone #: ###-####. Interior shear walls and holdowns, added hold downs on exterior walls at phase 2.
FIRE-Final Inspection12/8/201112/9/201112/9/2011APART
DetailsTroy Cobbley
The east side remodeled area life safety is passed.
FIRE-Final Inspection12/7/201112/8/201112/8/2011PFAIL
DetailsTroy Cobbley
This inspection was for the east side remodeled area only. The two exit discharge lights need to be repaired. Also a fire alarm sytem is shown to be installed but has not been. It appears to be only there to monitor the duct smoke detectors. I told the contractor that the remote annunciators as installed are ok if the fire alarm panel is installed. If it is not installed then the correct remote annunciators need to be installed. The duct smoke detectors will need to be tested when a decision has been made.
BLD-Other10/11/201110/12/201110/12/2011PPASS
DetailsMike Jordan
Soffit shear---Request early---Rob Phone #: ###-####
BLD-Framing/Rough-in10/4/201110/5/201110/5/2011APASS
DetailsMike Jordan
rob Phone #: ###-####Sofitt and barrel cieling ok.
BLD-Framing/Rough-in9/26/20119/27/20119/27/2011APART
DetailsMike Jordan
steel stud framing//Rob Phone #: ###-####. Interior steel stud walls only ok to cover. Need framing details for barrell ceiling. Aslo need to verifiy additional holdowns at extrior shear wall locations.
BLD-Other9/20/20119/21/20119/21/2011PPASS
DetailsMike Jordan
insulation and shear wall//Rob Phone #: ###-####. Wall and roof insulation on clere story ok. Nailing and hold downs on both interior shear walls ok.
BLD-Conference9/13/20119/14/20119/14/2011ADONE
DetailsMike Jordan
Rob Phone #: ###-####
BLD-Wall cover9/9/20119/9/20119/9/2011PPASS
DetailsMike Jordan
SHEAR ROOF---Rob Phone #: ###-####. Nails were used as per approved plan. roof ok, clere story ok.
BLD-Framing/Rough-in9/1/20119/2/20119/2/2011AFAIL
DetailsMike Jordan
Rob Phone #: ###-####. Needs to provide staple equivelabcy chart from engineer for shear walls on clere story and for osb attachment on clere story.
BLD-Foundation8/8/20118/9/20118/9/2011APASS
DetailsMike Jordan
Rob Phone #: ###-####. Stemwall for new vault wall. Also discussed required special inspections for project.
BLD-Footing8/3/20118/5/20118/5/2011PPASS
DetailsTom Arcoraci
Rob Phone #: ###-####