Permit Information
Permit NumberBLD11-01260
StatusFinaled
Name STETSON HOMES INC
Site Address 11477 W HIAWATHA DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 2,364 sq. ft., two story (first story 1,938 sq. ft., second story 381 sq. ft.) with 5 bedrooms, 3 bathrooms, approximately 208 sq. ft. of covered patio/porch and a 776 sq. ft. attached garage per the approved plans, plan review report and any notations. R-1A zoning and setbacks per planning. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/19/20119/19/20119/19/2011PPASS
DetailsMike Jordan
rustin Phone #: ###-####
DOC - Permit Finaled9/19/20119/19/20119/19/2011PPASS
DetailsMike Jordan
Handrail has been repaired. Residential certificate of occupancy was issued.
BLD-Final9/16/20119/16/20119/19/2011PFAIL
DetailsMike Jordan
russ Phone #: ###-####
BLD-Final9/15/20119/16/20119/16/2011ANR
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Rustin Ray. Needs electrical final first.
BLD-Energy code compliance8/22/20118/23/20118/23/2011APASS
DetailsMike Jordan
Rusten Phone #: ###-####
BLD-Energy code compliance8/21/20118/22/20118/22/2011AFAIL
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Rustin Ray
BLD-Energy code compliance8/19/20118/19/20118/19/2011PNR
DetailsJim Sly
Rustin Phone #: ###-####
Called Rustin....cannot OK to cover until Bonus room wall corrections are completed properly.
BLD-Energy code compliance8/18/20118/18/20118/18/2011PFAIL
DetailsMike Jordan
RUSTIN Phone #: ###-####. Provide top and bottom plates on knee walll for bonus room trusses.Provide load path on non bearing wall @ triple LVL for A3 and A4 trusses.
BLD-Framing/Rough-in8/17/20118/17/20118/17/2011PFAIL
DetailsMike Jordan
rustin Phone #: ###-####. Fireblocking and furouts for kneewalls and vaulted areas completed. ok to insulate. All other items not yet repaired.
BLD-Framing/Rough-in8/14/20118/15/20118/15/2011AFAIL
DetailsMike Jordan
Approved set of plans should be onsite. They might be in the tube out front. Phone #: ###-#### >> Inspection requested via web by Rustin Ray. Fireblock area at concelled space at tub/shower at ceiling, SeaL AROUND GAS PIPE PENETRATION THROUGH WALL AND BOTTOM PLATE (south wall), Connect bottom chord on C3 truss as per truss engineering. Provide code compliant steps from garage. Justify bearing point change on A3 and A4 truss, provide engineered fix from BMC. Fireblock at plumbing penetration by stairs. Bonus room knee wall trusses need to be furred out to accept R21 insulation and encapsulated. All other vaulted areas need to be encapsulated as well. Provide correct portal frame framing as shown on sheet 1 and 3 on approved plans. Correction notice posted, not ok to insulate.
BLD-Foundation6/27/20116/27/20116/27/2011PPART
DetailsMike Jordan
ben Phone #: ###-####
BLD-Footing6/24/20116/24/20116/24/2011PPASS
DetailsMike Jordan
BEN Phone #: ###-####