Permit Information
Permit NumberBLD11-01512
StatusFinaled
Name KABUL GROCERY LLC
Site Address 5751 W OVERLAND RD
Project NameKABUL MARKET
Customer Number 
ePlanReviewNo
Description
KABUL MARKET - Remodel and Expansion. ***5-4-2012 PLAN MODIFICATION TO INCLUDE: REMOVE COMMERCIAL KITCHEN COOKLINE FROM PROJECT.** NOTE: An Upgrade Agreement (attached to this case) exists on this building to upgrade the south exterior wall at a future date. Remodel of existing 2,301 sq. ft. Kubal Market for use as a 1,706 sq. ft. fast food restaurant with dining, kitchen & prep areas and expansion into adjoining 1,394 sq. ft. fire damaged previous Hooka Bar space for the 1,989 sq. ft. retail sales / display area, creating a 3,695 sq. ft. Kabul Market / Fast Food tenant space. Partial permit allowing select scope of work is being done under BLD11-01514. Work to include: Demolition work per plans; construction of interior non-bearing partitions walls to create; a new dining area, commercial kitchen area, two new fully accessible male and female restrooms, storage room, and mechanical room; install a new walk-in freezer; install new commercial kitchen fixtures including a new (type I) commercial kitchen exhaust hood and duct system, a new point of sale customer cashier counter; new interior and exterior lighting; electrical, mechanical and plumbing work; interior finishes in compliance with chapter 8 of the 2009 IBC; and all other work per the approved plans, attached plan review report, and all applicable codes. A new Certificate of Occupancy with the new occupant load total is required to be obtained after all work has been inspected and approved and prior to tenant occupying this space. This building is NOT fire sprinklered. **SRZ** DRH11-00120
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Other2/27/20152/27/20152/27/2015ADONE
DetailsBob Archibald
Provisions of upgrade agreement on south wall have not been completed.
BLD-Final5/10/20125/11/20125/11/2012PPASS
DetailsTom Arcoraci
Rahmat - life safety Phone #: ###-####
FIRE-Final Inspection5/10/20125/11/20125/11/2012APASS
DetailsTroy Cobbley
Life safety passed per plan modifications deleting the cooking line.
BLD-Conference5/10/20125/10/20125/10/2012PCANC
DetailsTom Arcoraci
To get final occupancy set up
BLD-Aging Inspection4/3/20124/3/20124/3/2012 PASS
DetailsTom Arcoraci
BLD-Final1/31/20122/1/20122/1/2012APART
DetailsTom Arcoraci
rahmet - after 10:00 please - call 1/2 hr prior Phone #: ###-#### ok for temp occ mech will be done when kitchen area is finished
FIRE-Final Inspection1/30/20121/31/20121/31/2012PPART
DetailsTroy Cobbley
A temporary occupancy is being given with Romeo Gervais permission until the kitchen area is complete. Per Sam, in plan review, the single action "paddle" hardware on the store front door from the Dining area is permissable.
FIRE-Final Inspection1/24/20121/25/20121/25/2012AFAIL
DetailsTroy Cobbley
It appears that the exit sign at the corridor leading to the dining area and panic hardware for the exterior exit from the dining area is still an issue. I spoke to Rob, the architect, and let him know that he needs to contact Sam in plan review about these issues.
FIRE-Final Inspection1/3/20121/4/20121/4/2012PFAIL
DetailsTroy Cobbley
Repair all exit signs/emergency lights, provide exit discharge lights per plan sheet A-101, provide panic hardware at door 102 per plan sheet A-101, provide sticker above the main exit door "Door to remain . . .....", provide ADA hardware for all pocket doors, relocate the hallway exit sign to the location shown per plan sheet A-101
BLD-Framing/Rough-in10/24/201110/24/201110/24/2011PPASS
DetailsTom Arcoraci
Rahmat Phone #: ###-####
FIRE-Conference10/11/201110/12/201110/12/2011ADONE
DetailsTroy Cobbley
Met with the owner, architect and the building inspector about scope of work changes and a possible temporary occupancy.
BLD-Conference10/11/201110/12/201110/12/2011APASS
DetailsTom Arcoraci
Rob Phone #: ###-#### must have ok from fire for temp occ without kitchen